FWCF3032VWA0601

Circuit Breakers

CIRCUIT BREAKER

FWCF3032VWA0601

5925-01-513-4475

5925 - Circuit Breakers

Westwood Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Case Material

    plastic

  • Auxiliary Switch Function And Quantity

    1 control

  • Switch Location And Position Designation

    internal at pole one

  • Operating Voltage Type And Rating Per Pole In Volts

    690.0 ac all locations

  • Center To Center Distance Between Terminals Parallel To Width

    34.930 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    18000.0 ac all locations

  • Boss Height

    4.170 inches nominal

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Body Width

    70.670 inches nominal

  • Nominal Thread Size

    0.164 inches

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    114.300 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Body Style

    multipole-single actuator type

  • Trip Release Ambient Temp Rating

    50.0 deg celsius nominal all locations

  • Switch Contact Arrangement

    single pole, double throw

  • Switch Current Rating And Type In Amps

    6.0 ac

  • Actuator Position Designation

    at pole two

  • Trip Release Method

    thermal-magnetic all locations

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Body Height

    85.730 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    32.0 amperes ac all locations

  • Center To Center Distance Between Terminals Parallel To Length

    119.080 inches nominal

  • Switch Terminal Type

    wire lead

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Actuator Function

    trip-reset

  • Body Length

    152.400 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    34.930 inches nominal

  • End Item Identification

    load ctr 28b ddg91

  • Ultimate Trip Time Per Pole In Seconds

    4.000 minimum all locations and 20.000 maximum all locations

  • Reset Method

    manual

  • Thread Series Designator

    unc

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Trip Release Characteristic

    instantaneous all locations

  • Special Features

    fixed thermal/magnetic trip; w/o terminals

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    200.0 all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...