BACC18AD7

Circuit Breakers

CIRCUIT BREAKER

BACC18AD7

5925-01-519-1312

5925 - Circuit Breakers

Boeing Defence Australia Ltd

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.400 minimum at 500 pct single location and 2.000 maximum at 500 pct single location and 0.100 minimum at 1000 pct single location and 4.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location and 0.530 maximum at 1000 pct

  • Center To Center Distance Between Terminals Parallel To Length

    0.694 inches minimum and 0.714 inches maximum

  • Body Length

    0.750 inches nominal

  • Bushing Length

    0.250 inches nominal

  • Reset Method

    manual

  • End Item Identification

    boeing b757 aircraft

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Manual Actuator Type And Quantity

    1 push-pull

  • Mounting Surface To Terminal End Distance

    1.302 inches minimum and 1.322 inches maximum

  • Pole Quantity

    1

  • Unpackaged Unit Weight

    30.000 grams

  • ~1

    single location

  • Special Features

    mounting bushing thread class 2a; operating altitude 0.0 to 70000.0 feet; operating force pull-out 1.5 to 5.0 pounds and reset force 1.0 to 5.0 pounds

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Body Width

    0.624 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 30.0 dc single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Terminal Type And Quantity

    2 tab w/screw

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2800.0 ac single location and 3400.0 dc single location

  • Nominal Thread Size

    0.4688 inches

  • Maximum Continuous Load Current Rating Per Pole

    7.500 amperes ac single location and 7.500 amperes dc single location

  • Thread Series Designator

    uns

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...