CA3-B0-26-650-13A-C

Circuit Breakers

CIRCUIT BREAKER

CA3-B0-26-650-13A-C

5925-01-519-1884

5925 - Circuit Breakers

Carling Technologies, Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • End Item Identification

    t6a training aircraft

  • Reset Method

    electric

  • Trip Release Characteristic

    instantaneous all locations

  • Terminal Type And Quantity

    1 solder stud

  • Arc Quenching Method

    air

  • Circuit Protection Type

    overvoltage all locations

  • Pole Quantity

    1

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3000.0 dc all locations

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes dc single location

  • Body Style

    single pole type

  • Mounting Facility Type And Quantity

    1 threaded stud

  • Trip Release Method

    solid state all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 dc single location

  • Case Material

    plastic