AP112-R-87059-044

Circuit Breakers

CIRCUIT BREAKER

AP112-R-87059-044

5925-01-519-2295

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Switch Terminal Type

    tab, solder lug

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Trip Release Characteristic

    time delay all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Actuator Function

    trip-reset

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations and 50.0 dc all locations

  • Nominal Thread Size

    0.375 inches

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac all locations and 20.0 amperes dc all locations

  • Trip Release Method

    magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Actuator Position Designation

    at pole two

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Switch Current Rating And Type In Amps

    0.5 ac and 0.5 dc

  • Body Width

    1.562 inches maximum

  • Thread Series Designator

    unef

  • Switch Voltage Rating And Type In Volts

    120.0 ac and 50.0 dc

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac single location and 500.0 dc single location

  • Body Length

    1.937 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 minimum at 200 pct all locations

  • Terminal Type And Quantity

    6 wire hook

  • Frequency In Hertz

    400.00 all locations

  • Bushing Length

    0.380 inches maximum

  • Switch Location And Position Designation

    internal at pole one

  • Switch Contact Arrangement

    single pole, double throw

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Body Style

    multipole-single actuator type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...