MIL-PRF-55629/21
Circuit Breakers
CIRCUIT BREAKER
MIL-PRF-55629/21
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Body Style
multipole-single actuator type
-
Case Material
metal
-
Part Name Assigned By Controlling Agency
mil spec: circuit breakers, magnetic, panel seal, trip-free, series trip, double pole
-
Bushing Length
0.625 inches nominal
-
Main Contact Tripping Mechanism Type
trip free
-
End Item Identification
mcs ln sw rk 48011322; machinery con
-
Center To Center Distance Between Terminals Parallel To Length
1.530 inches nominal
-
Mounting Surface To Terminal End Distance
2.232 inches maximum
-
Body Width
1.515 inches maximum
-
Inclosure Protection Type For Which Designed
fungus resistant and salt spray proof and moisture resistant and vibration resistant and explosion resistant and shock resistant
-
Thread Series Designator
un
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Circuit Protection Type
overcurrent all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc all locations
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.500 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations
-
Pole Quantity
2
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes dc all locations
-
Reset Method
manual
-
Nominal Thread Size
0.500 inches
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Trip Release Characteristic
time delay all locations
-
Body Length
2.000 inches nominal
-
Internal Trip Release Configuration
series trip all locations
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc all locations
-
Terminal Type And Quantity
4 tab w/screw
-
Thread Quantity Per Inch
32
-
Trip Release Method
magnetic all locations