PP11-1-0.500A-0B-V
Circuit Breakers
CIRCUIT BREAKER
PP11-1-0.500A-0B-V
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Part Name Assigned By Controlling Agency
cage: snapak series magnetic circuit protector
-
Case Material
plastic
-
Mounting Facility Type And Quantity
4 terminal
-
End Item Identification
c-10256c/brr-6 trident, control indicator; c-10256d/brr-6 trident, control indicator; ohio class ssbn
-
Frequency In Hertz
50.0 all locations or 60.0 all locations
-
Main Contact Tripping Mechanism Type
trip free
-
Trip Release Characteristic
time delay single location
-
Terminal Type And Quantity
4 knife blade
-
Body Style
multipole-single actuator type
-
Pole Quantity
1
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
135.0 single location
-
Manual Actuator Type And Quantity
1 push-pull
-
Trip Release Method
magnetic all locations
-
Circuit Protection Type
overcurrent single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 dc single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
135.0 all locations
-
Trip Delay Time In Seconds Per Rated Continuous Current
1.000 minimum at 200 pct all locations and 8.000 maximum at 200 pct all locations
-
Trip Release Characteristic
time delay all locations
-
Reset Method
manual
-
Overall Length
1.375 nominal inches
-
Circuit Protection Type
overcurrent all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 dc all locations
-
Body Width
1.304 inches nominal
-
Trip Release Method
magnetic single location