7271-3-3

Circuit Breakers

CIRCUIT BREAKER

7271-3-3

5925-01-585-0063

5925 - Circuit Breakers

Texas Instruments Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes ac single location and 3.0 amperes dc single location

  • Terminal Type And Quantity

    2 screw

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Trip Release Ambient Temp Rating

    -40.0 deg celsius minimum single location and 71.0 deg celsius nominal single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Nominal Thread Size

    6.0 millimeters

  • Manual Actuator Type And Quantity

    1 push-pull

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches minimum and 0.937 inches maximum

  • Part Name Assigned By Controlling Agency

    drawing: 7271-3 type push-pull trip-free circuit breaker

  • Pole Quantity

    1

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Bushing Length

    0.313 inches minimum and 0.375 inches maximum

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Body Length

    2.187 inches maximum

  • Special Features

    push-pull actuator marked with amp rating (3) on top

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    4000.0 ac single location and 3500.0 dc single location

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 30.0 dc single location

  • ~1

    single location

  • Body Width

    0.750 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.781 inches minimum and 1.843 inches maximum

  • Mounting Surface To Terminal End Distance

    1.281 inches minimum and 1.343 inches maximum

  • Case Material

    plastic

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • End Item Identification

    spanish air force

  • Trip Delay Time In Seconds Per Rated Continuous Current

    40.000 minimum at 200 pct single location and 1.000 minimum at 600 pct single location and 26.000 maximum at 400 pct single location and 200.000 maximum at 200 pct single location and 3.000 minimum at 400 pct single location and 12.000 maximum at 600 pct

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...