SAE-AS26574
Circuit Breakers
CIRCUIT BREAKER
SAE-AS26574
Society Of Automotive Engineers Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Trip Release Method
magnetic single location
-
Bushing Length
0.250 inches nominal
-
Reset Method
manual
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 ac single location and 500.0 dc single location
-
Actuator Function
trip-reset
-
Terminal Type And Quantity
2 screw
-
Thread Quantity Per Inch
32
-
Nominal Thread Size
0.438 inches
-
Circuit Protection Type
overcurrent single location
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Manual Actuator Type And Quantity
1 push-pull
-
End Item Identification
overhead panel assy; new zealand airforce
-
Pole Quantity
1
-
Case Material
metal
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location
-
Internal Trip Release Configuration
series trip single location
-
Operating Voltage Type And Rating Per Pole In Volts
200.0 ac single location and 28.0 dc single location
-
Trip Release Characteristic
time delay single location
-
Main Contact Tripping Mechanism Type
trip free
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac single location and 15.0 amperes dc single location
-
Body Length
0.790 inches maximum
-
Frequency In Hertz
400.0 single location
-
Body Style
single pole type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 single location
-
Special Features
extra-long pushbutton 0.782 in. closed to 1.134 in. tripped
-
Thread Series Designator
un
-
Body Width
0.593 inches maximum
-
Mounting Surface To Terminal End Distance
1.251 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
0.593 inches nominal