Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Terminal Type And Quantity

    4 screw

  • Nominal Thread Size

    0.375 inches

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Special Features

    includes (2) 6-32 threaded plug inserts for mounting

  • Body Style

    multipole-single actuator type

  • Part Name Assigned By Controlling Agency

    ap fully sealed magnetic circuit breaker, 2 pole unit, screw terminals, bushing plus (2) 6-32 threaded inserts, series, 50/60hz high pulse long time delay

  • Manual Actuator Type And Quantity

    1 toggle

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac all locations

  • Actuator Position Designation

    between pole one and two

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.150 minimum at 200 pct all locations and 7.000 maximum at 200 pct all locations

  • Body Length

    1.562 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    800.0 all locations

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Thread Series Designator

    unef

  • Body Width

    1.281 inches maximum

  • Bushing Length

    0.380 inches maximum

  • Case Material

    plastic

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Maximum Continuous Load Current Rating Per Pole

    1000.0 amperes ac all locations

  • Reset Method

    manual

  • Trip Release Method

    magnetic all locations

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Trip Release Characteristic

    time delay all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...