NSN: 5905-00-086-1520
Resistors
RESISTOR,THERMAL
RESISTOR,THERMAL
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Resistance Tolerance At A Specified Temp In Percent
-16.6/+16.6 2nd resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-18.9/+18.9 1st resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
104.4 deg celsius 8th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-20.1/+20.1 10th resistance-temperature point
-
Body Outside Diameter
0.112 inches nominal
-
Resistance Tolerance At A Specified Temp In Percent
-18.9/+18.9 9th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-14.2/+14.2 3rd resistance-temperature point
-
Zero Power Resistance At Specified Temp
129.0 ohms 10th resistance-temperature point
-
Cubic Measure
0.007 cubic inches
-
Temp Points For Resistance Readings At Zero Power
-21.5 deg celsius 3rd resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
150.0 deg celsius 10th resistance-temperature point
-
Zero Power Resistance Tolerance In Percent At Reference Temp
-10.0/+10.0
-
Resistance Tolerance At A Specified Temp In Percent
-17.8/+17.8 8th resistance-temperature point
-
Terminal Surface Treatment
solder
-
Maximum Operating Temp
150.0 deg celsius
-
Zero Power Resistance At Specified Temp
232.0 kilohms 1st resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
125.0 deg celsius 9th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-15.1/+15.1 6th resistance-temperature point
-
Zero Power Resistance At Specified Temp
93.3 kilohms 2nd resistance-temperature point
-
Zero Power Resistance At Specified Temp
34.4 kilohms 3rd resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
37.8 deg celsius 5th resistance-temperature point
-
Thermal Time Constant In Seconds
50.0
-
Temp Points For Resistance Readings At Zero Power
50.0 deg celsius 6th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
-40.0 deg celsius 2nd resistance-temperature point
-
Terminal Diameter
0.020 inches nominal
-
Resistance Tolerance At A Specified Temp In Percent
-16.9/+16.9 7th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
-55.0 deg celsius 1st resistance-temperature point
-
Zero Power Resistance At Specified Temp
12.1 kilohms 4th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
75.0 deg celsius 7th resistance-temperature point
-
Zero Power Resistance At Specified Temp
1.8 kilohms 6th resistance-temperature point
-
Reference Temp In Deg Celsius
25.0
-
Zero Power Resistance At Specified Temp
2.6 kilohms 5th resistance-temperature point
-
Power Dissipation Constant In Milliwatts Per Deg Celsius
6.0
-
Zero Power Resistance At Specified Temp
217.2 ohms 9th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
0.0 deg celsius 4th resistance-temperature point
-
Ambient Temp At Full Rated Power
25.0 deg celsius
-
Zero Power Resistance At Specified Temp
774.0 ohms 7th resistance-temperature point
-
Unpackaged Unit Weight
1.719 grams
-
Style Designator
rod
-
Terminal Length
1.500 inches nominal
-
Terminal Type And Quantity
2 wire lead
-
Reliability Indicator
not established
-
Inclosure Type
encapsulated
-
Resistance Tolerance At A Specified Temp In Percent
-13.7/+13.7 5th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-12.6/+12.6 4th resistance-temperature point
-
Zero Power Resistance
4.300 kilohms
-
Body Length
0.900 inches nominal
-
Zero Power Resistance At Specified Temp
352.6 ohms 8th resistance-temperature point