NSN: 5905-00-418-8718
Resistors
RESISTOR,THERMAL
RESISTOR,THERMAL
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Temp Points For Resistance Readings At Zero Power
100.0 deg celsius 8th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
-25.0 deg celsius 4th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
-65.0 deg celsius 2nd resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
-75.0 deg celsius 1st resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
75.0 deg celsius 7th resistance-temperature point
-
Zero Power Resistance At Specified Temp
1.1 kilohms 10th resistance-temperature point
-
Zero Power Resistance At Specified Temp
229.5 ohms 1st resistance-temperature point
-
Zero Power Resistance At Specified Temp
249.9 ohms 2nd resistance-temperature point
-
Zero Power Resistance At Specified Temp
285.6 ohms 3rd resistance-temperature point
-
Zero Power Resistance At Specified Temp
423.3 ohms 5th resistance-temperature point
-
Zero Power Resistance At Specified Temp
601.8 ohms 6th resistance-temperature point
-
Zero Power Resistance At Specified Temp
714.0 ohms 7th resistance-temperature point
-
Zero Power Resistance At Specified Temp
994.5 ohms 9th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-10.1 to 10.1 10th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-6.7 to 6.7 4th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-7.2 to 7.2 7th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-8.5 to 8.5 8th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-9.2 to 9.2 9th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-6.6 to 6.6 6th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-7.4 to 7.4 3rd resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-8.0 to 8.0 2nd resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-8.3 to 8.3 1st resistance-temperature point
-
Inclosure Type
encapsulated
-
Zero Power Resistance
510.000 ohms
-
Reference Temp In Deg Celsius
25.0
-
Style Designator
15 rod
-
Zero Power Resistance Tolerance In Percent At Reference Temp
-5.0 to 5.0
-
Test Data Document
90073-469-508 drawing
-
Terminal Type And Quantity
2 wire lead
-
Terminal Length
1.500 inches nominal
-
Body Outside Diameter
0.215 inches maximum
-
Maximum Power Dissipation Rating
250.00 milliwatts
-
Power Dissipation Constant In Milliwatts Per Deg Celsius
2.0
-
Zero Power Temp Coefficient Of Resistance In Percent Per Deg Celsius
0.70
-
Temp Points For Resistance Readings At Zero Power
125.0 deg celsius 9th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
150.0 deg celsius 10th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
-50.0 deg celsius 3rd resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
50.0 deg celsius 6th resistance-temperature point
-
Zero Power Resistance At Specified Temp
346.8 ohms 4th resistance-temperature point
-
Zero Power Resistance At Specified Temp
831.3 ohms 8th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-5.3 to 5.3 5th resistance-temperature point
-
Reliability Indicator
not established
-
Body Length
0.600 inches maximum
-
Terminal Diameter
0.250 inches nominal
-
Ambient Temp At Full Rated Power
25.0 deg celsius
-
Maximum Operating Temp
125.0 deg celsius
-
Thermal Time Constant In Seconds
60.0
-
Temp Points For Resistance Readings At Zero Power
0.0 deg celsius 5th resistance-temperature point