NSN: 5905-00-419-2590
Resistors
RESISTOR,THERMAL
RESISTOR,THERMAL
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Terminal Surface Treatment
solder
-
Zero Power Resistance At Specified Temp
40.4 ohms 5th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
-25.0 deg celsius 4th resistance-temperature point
-
Zero Power Resistance At Specified Temp
71.9 ohms 8th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
125.0 deg celsius 9th resistance-temperature point
-
Zero Power Resistance At Specified Temp
62.7 ohms 7th resistance-temperature point
-
Zero Power Resistance Tolerance In Percent At Reference Temp
-5.0/+5.0
-
Temp Points For Resistance Readings At Zero Power
50.0 deg celsius 6th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-8.0/+8.0 2nd resistance-temperature point
-
Body Length
0.270 inches minimum and 0.300 inches maximum
-
Zero Power Resistance At Specified Temp
83.2 ohms 9th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-8.3/+8.3 1st resistance-temperature point
-
Power Dissipation Constant In Milliwatts Per Deg Celsius
2.5
-
Resistance Tolerance At A Specified Temp In Percent
-7.2/+7.2 7th resistance-temperature point
-
Maximum Operating Temp
125.0 deg celsius
-
Zero Power Resistance At Specified Temp
29.6 ohms 3rd resistance-temperature point
-
Zero Power Resistance At Specified Temp
34.8 ohms 4th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
0.0 deg celsius 5th resistance-temperature point
-
Style Designator
rod
-
Terminal Type And Quantity
2 wire lead
-
Reliability Indicator
not established
-
Maximum Power Dissipation Rating
125.00 milliwatts
-
Resistance Tolerance At A Specified Temp In Percent
-8.5/+8.5 8th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-7.4/+7.4 3rd resistance-temperature point
-
Thermal Time Constant In Seconds
35.0
-
Temp Points For Resistance Readings At Zero Power
-65.0 deg celsius 2nd resistance-temperature point
-
Body Outside Diameter
0.085 inches minimum and 0.105 inches maximum
-
Inclosure Type
hermetically sealed
-
Zero Power Resistance
47.000 ohms
-
Zero Power Resistance At Specified Temp
25.4 ohms 1st resistance-temperature point
-
Zero Power Resistance At Specified Temp
27.3 ohms 2nd resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-10.1/+10.1 10th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
150.0 deg celsius 10th resistance-temperature point
-
Zero Power Temp Coefficient Of Resistance In Percent Per Deg Celsius
0.70
-
Temp Points For Resistance Readings At Zero Power
100.0 deg celsius 8th resistance-temperature point
-
Zero Power Resistance At Specified Temp
54.1 ohms 6th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-5.3/+5.3 5th resistance-temperature point
-
Ambient Temp At Full Rated Power
100.0 deg celsius
-
Terminal Diameter
0.020 inches nominal
-
Terminal Length
1.000 inches minimum
-
Temp Points For Resistance Readings At Zero Power
75.0 deg celsius 7th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
-50.0 deg celsius 3rd resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-6.6/+6.6 6th resistance-temperature point
-
Zero Power Resistance At Specified Temp
93.9 ohms 10th resistance-temperature point
-
Reference Temp In Deg Celsius
25.0
-
Resistance Tolerance At A Specified Temp In Percent
-9.2/+9.2 9th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
-75.0 deg celsius 1st resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-6.7/+6.7 4th resistance-temperature point