NSN: 5905-00-492-1937
Resistors
RESISTOR,THERMAL
RESISTOR,THERMAL
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
~1
data on certain environmental and performance
-
Test Data Document
81349-milr23648 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Temp Points For Resistance Readings At Zero Power
50.0 deg celsius 4th resistance-temperature point
-
Zero Power Resistance At Specified Temp
7.4 kilohms 2nd resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-20.0/+20.0 1st resistance-temperature point
-
Power Dissipation Constant In Milliwatts Per Deg Celsius
5.0
-
Body Width
0.260 inches maximum
-
Zero Power Resistance Tolerance In Percent At Reference Temp
-10.0/+10.0
-
Zero Power Resistance At Specified Temp
148.0 ohms 5th resistance-temperature point
-
Zero Power Resistance At Specified Temp
34.0 ohms 7th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
-15.0 deg celsius 2nd resistance-temperature point
-
Zero Power Resistance At Specified Temp
3.3 kilohms 3rd resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
125.0 deg celsius 7th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
-55.0 deg celsius 1st resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-12.0/+12.0 4th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-12.0/+12.0 3rd resistance-temperature point
-
Maximum Power Dissipation Rating
500.00 milliwatts
-
Temp Points For Resistance Readings At Zero Power
100.0 deg celsius 6th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-17.0/+17.0 6th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-14.0/+14.0 5th resistance-temperature point
-
Inclosure Type
encapsulated
-
Resistance Tolerance At A Specified Temp In Percent
-14.0/+14.0 2nd resistance-temperature point
-
Zero Power Resistance At Specified Temp
67.5 ohms 6th resistance-temperature point
-
Reliability Indicator
not established
-
Style Designator
spherical
-
Terminal Type And Quantity
2 wire lead
-
Ambient Temp At Full Rated Power
25.0 deg celsius
-
Body Outside Diameter
0.250 inches nominal
-
Terminal Length
1.500 inches minimum
-
Zero Power Temp Coefficient Of Resistance In Percent Per Deg Celsius
-29.40
-
Maximum Operating Temp
125.0 deg celsius
-
Temp Points For Resistance Readings At Zero Power
0.0 deg celsius 3rd resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-20.0/+20.0 7th resistance-temperature point
-
Zero Power Resistance At Specified Temp
360.0 ohms 4th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
75.0 deg celsius 5th resistance-temperature point
-
Terminal Diameter
0.020 inches nominal
-
Thermal Time Constant In Seconds
80.0
-
Zero Power Resistance
1.000 kilohms
-
Zero Power Resistance At Specified Temp
100.0 kilohms 1st resistance-temperature point