NSN: 5905-00-791-5866
Resistors
RESISTOR,VARIABLE,WIRE WOUND,PRECISION
RESISTOR,VARIABLE,WIRE WOUND,PRECISION
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Terminal Type And Quantity
26 turret
-
Power Dissipation Rating Per Section In Watts
0.1 free air all sections
-
Test Data Document
20418-es2205 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Function Characteristic Per Section
all sections table
-
Section Quantity
5
-
Overall Diameter
1.315 inches maximum
-
Mounting Lip Depth
0.0620 inches nominal
-
Body Length
3.621 inches maximum
-
Electrical Resistance Per Section
4.0 percent, rated amperes c and better finish
-
Function Conformity Tolerance Per Section
-1.50/+1.50 1st section
-
Resistance Tolerance Per Section In Percent
-5.0/+5.0 all sections
-
Shaft Style
round
-
Pilot Diameter
1.0300 inches nominal
-
Function Conformity Tolerance Per Section
-1.50/+1.50 4th section
-
Body Diameter
1.130 inches maximum
-
Body Style
cylindrical servo mounted
-
Lateral Runout
0.001 inches
-
Electrical Resistance Per Section
20.0 percent, rated amperes c and better industrial clears
-
Function Conformity Tolerance Per Section
-1.50/+1.50 5th section
-
Mounting Lip Diameter
1.0930 inches nominal
-
Electrical Resistance Per Section
20.0 percent, rated amperes c and better select
-
Undercut Diameter
1.000 inches maximum
-
Shaft Diameter
0.125 inches nominal
-
Rotary Actuator Travel In Angular Deg
360.0 nominal
-
Pilot Length
0.0620 inches nominal
-
Undercut Width
0.0620 inches nominal
-
Actuator Type
single shaft
-
Reliability Indicator
not established
-
Actuator Travel Control Feature
continuous motion
-
Function Conformity Per Section
all sections proportional conformity
-
Temp Coefficient Of Resistance Per Section In Ppm Per Deg Celsius
-40.0/+40.0 all sections
-
Mounting Method
clamp ring
-
Electrical Resistance Per Section
80.0 percent, rated amperes c drop siding
-
Terminal Location
radially positioned over less than half the circumference
-
Function Conformity Tolerance Per Section
-1.00/+1.00 2nd section
-
Overall Length
4.137 inches maximum
-
Electrical Resistance Per Section
40.0 percent, rated amperes c and better v.g. stepping
-
Function Conformity Tolerance Per Section
-1.00/+1.00 3rd section
-
Shaft Runout
0.001 inches
-
Maximum Starting Torque
1.50 inch-ounces
-
Shaft Length
0.500 inches nominal
-
Shaft Radial Play
0.008 inches
-
Ambient Temp In Deg Celsius Per Section At Full Rated Power
71.0 all sections