NSN: 5905-00-863-5590
Resistors
RESISTOR,VARIABLE,NONWIRE WOUND,PRECISION
RESISTOR,VARIABLE,NONWIRE WOUND,PRECISION
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Actuator Type
single shaft
-
Reliability Indicator
not established
-
Function Conformity Tolerance Per Section
-0.50/+0.50 single section
-
Actuator Travel Control Feature
continuous motion
-
Tap Location Tolerance Per Section
-20.0/+0.0 ohms single section
-
Special Features
0.033 in. dia through hole 0.156 in. from shaft end
-
Mounting Method
clamp ring
-
Tap Location From Ccw Terminal Per Section In Ohms
250.0 single section
-
Shaft Runout
0.001 inches
-
Function Characteristic Per Section
single section graph
-
Features Provided
humidity proof
-
Pilot Diameter
1.8750 inches maximum
-
Ambient Temp In Deg Celsius Per Section At Full Rated Power
25.0 single section
-
Undercut Diameter
1.870 inches nominal
-
Terminal Type And Quantity
4 turret
-
Resistance Tolerance Per Section In Percent
-20.0/+0.0 single section
-
Section Quantity
1
-
Terminal Location
radially positioned over more than half the circumference
-
Shaft Length
0.750 inches nominal
-
Function Conformity Per Section
single section absolute conformity
-
Test Data Document
19200-1054539 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Undercut Width
0.0550 inches minimum
-
Power Dissipation Rating Per Section In Watts
4.0 free air single section
-
Temp Coefficient Of Resistance Per Section In Ppm Per Deg Celsius
-400.0/+400.0 single section
-
Mounting Lip Depth
0.0550 inches minimum
-
Body Length
1.050 inches maximum
-
Body Diameter
2.005 inches maximum
-
Ambient Temp In Deg Celsius Per Section At Zero Percent Rated Power
150.0 single section
-
Electrical Resistance Per Section
500.0 ohms single section
-
Pilot Diameter Runout
0.001 inches
-
Shaft Style
round
-
Mounting Lip Diameter
2.0050 inches maximum
-
Pilot Length
0.0670 inches maximum
-
Body Style
cylindrical servo mounted
-
Fixed Tap Quantity Per Section
1 single section
-
Maximum Starting Torque
1.00 inch-ounces
-
Maximum Running Torque
1.00 inch-ounces
-
Effective Electrical Rotation In Deg Angular Rotation
180.0 minimum
-
Shaft Diameter
0.250 inches maximum
-
Rotary Actuator Travel In Angular Deg
360.0 nominal
-
Lateral Runout
0.002 inches