NSN: 5905-00-912-0334
Resistors
RESISTOR,THERMAL
RESISTOR,THERMAL
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Resistance Tolerance At A Specified Temp In Percent
-10.0/+10.0 4th resistance-temperature point
-
Inclosure Type
encapsulated
-
Cubic Measure
0.004 cubic inches
-
Resistance Tolerance At A Specified Temp In Percent
-15.0/+15.0 6th resistance-temperature point
-
Zero Power Resistance At Specified Temp
30.0 ohms 4th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
104.4 deg celsius 8th resistance-temperature point
-
Zero Power Resistance At Specified Temp
16.75 ohms 5th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
25.0 deg celsius 3rd resistance-temperature point
-
Thermal Time Constant In Seconds
15.0
-
Zero Power Resistance At Specified Temp
4.11 ohms 8th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-30.0/+30.0 1st resistance-temperature point
-
Zero Power Resistance At Specified Temp
2.57 kilohms 1st resistance-temperature point
-
Zero Power Resistance Tolerance In Percent At Reference Temp
-10.0/+10.0
-
Power Dissipation Constant In Milliwatts Per Deg Celsius
11.8
-
Terminal Surface Treatment
solder
-
Maximum Operating Temp
150.0 deg celsius
-
Zero Power Resistance At Specified Temp
5.98 ohms 7th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
-40.0 deg celsius 2nd resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
55.0 deg celsius 5th resistance-temperature point
-
Terminal Diameter
0.020 inches nominal
-
Temp Points For Resistance Readings At Zero Power
75.0 deg celsius 6th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-20.0/+20.0 3rd resistance-temperature point
-
Body Width
0.130 inches nominal
-
Zero Power Resistance At Specified Temp
1.03 kilohms 2nd resistance-temperature point
-
Style Designator
disk
-
Resistance Tolerance At A Specified Temp In Percent
-20.0/+20.0 8th resistance-temperature point
-
Reference Temp In Deg Celsius
37.8
-
Zero Power Resistance At Specified Temp
48.1 ohms 3rd resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
90.0 deg celsius 7th resistance-temperature point
-
Ambient Temp At Full Rated Power
25.0 deg celsius
-
Terminal Length
1.500 inches nominal
-
Terminal Type And Quantity
2 wire lead
-
Resistance Tolerance At A Specified Temp In Percent
-18.0/+18.0 7th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-27.0/+27.0 2nd resistance-temperature point
-
Zero Power Resistance
30.000 ohms
-
Reliability Indicator
not established
-
Zero Power Resistance At Specified Temp
9.08 ohms 6th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-13.0/+13.0 5th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
37.8 deg celsius 4th resistance-temperature point
-
Body Outside Diameter
0.405 inches nominal
-
Temp Points For Resistance Readings At Zero Power
-55.0 deg celsius 1st resistance-temperature point