NSN: 5905-00-929-7938

Resistors

RESISTOR,VARIABLE,WIRE WOUND,PRECISION

5905 - Resistors

RESISTOR,VARIABLE,WIRE WOUND,PRECISION

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation

    12.0 7th section and 0.0 7th section and 109.0 7th section and 140.0 7th section and 152.0 7th section and 48.0 7th section and 128.0 7th section and 350.0 7th section

  • Fragility Factor

    moderately rugged

  • Body Length

    3.360 inches minimum and 3.400 inches maximum

  • Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation

    0.0 5th section and 175.0 5th section and 115.0 5th section and 12.0 5th section and 80.0 5th section and 200.0 5th section and 187.0 5th section and 350.0 5th section

  • Power Dissipation Rating Per Section In Watts

    0.25 free air all sections

  • Mechanical Backlash In Deg Angular Rotation

    0.25

  • Mounting Stud Length

    0.250 inches minimum and 0.281 inches maximum

  • Fixed Tap Quantity Per Section

    8 1st section

  • Terminal Type And Quantity

    77 turret

  • Shaft End Play

    0.001 inches

  • Shaft Radial Play

    0.001 inches

  • Body Style

    cylindrical servo mounted

  • Maximum Running Torque

    4.00 inch-ounces

  • Test Data Document

    80045-361644 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

  • Shaft Diameter

    0.1245 inches minimum and 0.1250 inches maximum

  • Screw Thread Diameter

    0.112 inches nominal

  • Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation

    187.0 1st section and 280.0 1st section and 153.0 1st section and 213.0 1st section and 0.0 1st section and 313.0 1st section and 166.0 1st section and 350.0 1st section

  • Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation

    177.0 6th section and 119.0 6th section and 198.0 6th section and 53.0 6th section and 0.0 6th section and 12.0 6th section and 150.0 6th section and 350.0 6th section

  • Mounting Method

    clamp ring and threaded stud

  • Shaft Style

    round, slotted

  • Function Characteristic Per Section

    all sections linear

  • Screw Thread Quantity Per Inch

    40.0

  • Shaft Bearing Type

    bearing

  • Section Quantity

    8

  • Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation

    137.0 2nd section and 161.0 2nd section and 313.0 2nd section and 263.0 2nd section and 184.0 2nd section and 296.0 2nd section and 149.0 2nd section and 0.0 2nd section and 350.0 2nd section

  • Undercut Width

    0.0570 inches minimum and 0.0670 inches maximum

  • Unpackaged Unit Weight

    6.0 grams

  • Function Conformity Per Section

    all sections absolute linearity

  • Fixed Tap Quantity Per Section

    8 5th section

  • Fixed Tap Quantity Per Section

    8 6th section

  • Shaft Length

    0.734 inches minimum and 0.766 inches maximum

  • Fixed Tap Quantity Per Section

    8 7th section

  • Rotary Actuator Travel In Angular Deg

    360.0 nominal

  • Mounting Lip Diameter

    1.0520 inches minimum and 1.0670 inches maximum

  • Tap Location Tolerance Per Section

    -1.0/+1.0 deg angular rotation all sections

  • Undercut Diameter

    1.052 inches minimum and 1.067 inches maximum

  • Actuator Type

    single shaft

  • Function Conformity Tolerance Per Section

    -0.50/+0.50 all sections

  • Reliability Indicator

    not established

  • Screw Thread Series Designator

    unc

  • Actuator Travel Control Feature

    continuous motion

  • Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation

    195.0 4th section and 220.0 4th section and 207.0 4th section and 118.0 4th section and 130.0 4th section and 0.0 4th section and 170.0 4th section and 142.0 4th section and 350.0 4th section

  • Mounting Facility Quantity

    2

  • Maximum Starting Torque

    4.00 inch-ounces

  • Fixed Tap Quantity Per Section

    9 2nd section

  • Mounting Lip Depth

    0.0570 inches minimum and 0.0670 inches maximum

  • Resistance Tolerance Per Section In Percent

    -10.0/+10.0 all sections

  • Fixed Tap Quantity Per Section

    9 3rd section

  • Temp Coefficient Of Resistance Per Section In Ppm Per Deg Celsius

    -50.0/+50.0 all sections

  • Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation

    158.0 3rd section and 0.0 3rd section and 134.0 3rd section and 170.0 3rd section and 234.0 3rd section and 222.0 3rd section and 210.0 3rd section and 146.0 3rd section and 350.0 3rd section

  • Effective Electrical Rotation In Deg Angular Rotation

    360.0 nominal

  • Fixed Tap Quantity Per Section

    9 4th section

  • Pilot Diameter

    0.9683 inches minimum and 0.9688 inches maximum

  • Features Provided

    humidity proof

  • Pilot Length

    0.0570 inches minimum and 0.0670 inches maximum

  • Body Diameter

    1.099 inches minimum and 1.109 inches maximum

  • Terminal Location

    radially positioned over more than half the circumference

  • Electrical Resistance Per Section

    5.0 kilohms all sections

  • Ambient Temp In Deg Celsius Per Section At Full Rated Power

    100.0 all sections

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...