NSN: 5905-00-949-8552
Resistors
RESISTOR,THERMAL
RESISTOR,THERMAL
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Width
0.086 inches nominal
-
Resistance Tolerance At A Specified Temp In Percent
-11.5/+11.5 3rd resistance-temperature point
-
Zero Power Resistance At Specified Temp
140.5 kilohms 1st resistance-temperature point
-
Power Dissipation Constant In Milliwatts Per Deg Celsius
8.0
-
Inclosure Type
uninclosed
-
Zero Power Resistance At Specified Temp
9.7 kilohms 2nd resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
120.0 deg celsius 8th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
100.0 deg celsius 7th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
70.0 deg celsius 6th resistance-temperature point
-
Thermal Time Constant In Seconds
48.0
-
Zero Power Resistance At Specified Temp
175.2 ohms 6th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-13.8/+13.8 7th resistance-temperature point
-
Terminal Diameter
0.020 inches nominal
-
Maximum Operating Temp
200.0 deg celsius
-
Resistance Tolerance At A Specified Temp In Percent
-12.5/+12.5 6th resistance-temperature point
-
Zero Power Resistance At Specified Temp
6.6 ohms 10th resistance-temperature point
-
Zero Power Resistance At Specified Temp
360.0 ohms 5th resistance-temperature point
-
Reference Temp In Deg Celsius
25.0
-
Style Designator
disk
-
Resistance Tolerance At A Specified Temp In Percent
-17.0/+17.0 10th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-15.8/+15.8 9th resistance-temperature point
-
Zero Power Resistance At Specified Temp
1.2 kilohms 4th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
0.0 deg celsius 3rd resistance-temperature point
-
Ambient Temp At Full Rated Power
25.0 deg celsius
-
Resistance Tolerance At A Specified Temp In Percent
-13.0/+13.0 2nd resistance-temperature point
-
Terminal Length
1.500 inches nominal
-
Temp Points For Resistance Readings At Zero Power
-60.0 deg celsius 1st resistance-temperature point
-
Terminal Type And Quantity
2 wire lead
-
Reliability Indicator
not established
-
Body Outside Diameter
0.300 inches nominal
-
Resistance Tolerance At A Specified Temp In Percent
-14.6/+14.6 8th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-16.6/+16.6 1st resistance-temperature point
-
Cubic Measure
0.005 cubic inches
-
Zero Power Resistance Tolerance In Percent At Reference Temp
-10.0/+10.0
-
Terminal Surface Treatment
solder
-
Temp Points For Resistance Readings At Zero Power
160.0 deg celsius 9th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-11.5/+11.5 5th resistance-temperature point
-
Zero Power Resistance At Specified Temp
3.3 kilohms 3rd resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
20.0 deg celsius 4th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
-20.0 deg celsius 2nd resistance-temperature point
-
Zero Power Resistance At Specified Temp
18.6 ohms 9th resistance-temperature point
-
Zero Power Resistance At Specified Temp
38.9 ohms 8th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
50.0 deg celsius 5th resistance-temperature point
-
Zero Power Resistance At Specified Temp
67.8 ohms 7th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
200.0 deg celsius 10th resistance-temperature point
-
Zero Power Resistance
1.000 kilohms
-
Resistance Tolerance At A Specified Temp In Percent
-10.2/+10.2 4th resistance-temperature point