NSN: 5905-00-992-2595
Resistors
RESISTOR,THERMAL
RESISTOR,THERMAL
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Zero Power Resistance At Specified Temp
33.89 ohms 9th resistance-temperature point
-
Zero Power Resistance At Specified Temp
174.7 ohms 7th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-15.9/+15.9 8th resistance-temperature point
-
Style Designator
wafer
-
Resistance Tolerance At A Specified Temp In Percent
-18.9/+18.9 10th resistance-temperature point
-
Zero Power Resistance At Specified Temp
3.274 kilohms 4th resistance-temperature point
-
Cubic Measure
0.003 cubic inches
-
Inclosure Type
encapsulated
-
Zero Power Resistance At Specified Temp
67.54 ohms 8th resistance-temperature point
-
Zero Power Resistance At Specified Temp
359.5 ohms 6th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-16.0/+16.0 1st resistance-temperature point
-
Power Dissipation Constant In Milliwatts Per Deg Celsius
3.1
-
Resistance Tolerance At A Specified Temp In Percent
-17.5/+17.5 9th resistance-temperature point
-
Body Height
0.160 inches maximum
-
Temp Points For Resistance Readings At Zero Power
150.0 deg celsius 10th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
100.0 deg celsius 8th resistance-temperature point
-
Body Length
0.160 inches maximum
-
Resistance Tolerance At A Specified Temp In Percent
-12.0/+12.0 4th resistance-temperature point
-
Thermal Time Constant In Seconds
5.0
-
Temp Points For Resistance Readings At Zero Power
70.0 deg celsius 7th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
-55.0 deg celsius 1st resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-12.0/+12.0 6th resistance-temperature point
-
Zero Power Resistance Tolerance In Percent At Reference Temp
-10.0/+10.0
-
Terminal Surface Treatment
solder
-
Unpackaged Unit Weight
1.500 grams
-
Resistance Tolerance At A Specified Temp In Percent
-14.8/+14.8 2nd resistance-temperature point
-
Zero Power Resistance At Specified Temp
805.3 ohms 5th resistance-temperature point
-
Center To Center Distance Between Mounting Facilities Parallel To Width
0.100 inches nominal
-
Zero Power Temp Coefficient Of Resistance In Percent Per Deg Celsius
-4.40
-
Terminal Diameter
0.013 inches nominal
-
Maximum Operating Temp
150.0 deg celsius
-
Zero Power Resistance At Specified Temp
18.43 ohms 10th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
-20.0 deg celsius 3rd resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
125.0 deg celsius 9th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
50.0 deg celsius 6th resistance-temperature point
-
Zero Power Resistance At Specified Temp
100.0 kilohms 1st resistance-temperature point
-
Zero Power Resistance
1.000 kilohms
-
Temp Points For Resistance Readings At Zero Power
-40.0 deg celsius 2nd resistance-temperature point
-
Body Width
0.100 inches maximum
-
Reference Temp In Deg Celsius
25.0
-
Zero Power Resistance At Specified Temp
34.28 kilohms 2nd resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
30.0 deg celsius 5th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-13.5/+13.5 3rd resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-10.4/+10.4 5th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-13.5/+13.5 7th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
0.0 deg celsius 4th resistance-temperature point
-
Ambient Temp At Full Rated Power
25.0 deg celsius
-
Terminal Length
1.250 inches minimum
-
Terminal Type And Quantity
2 wire lead
-
Reliability Indicator
not established
-
Zero Power Resistance At Specified Temp
9.792 kilohms 3rd resistance-temperature point