NSN: 5915-00-001-5945
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Principal Circuitry Type Per Function
inductance-capacitance 4th radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 5th radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 6th radio interference
-
Operating Voltage Rating And Type Per Function
28.0 volts dc 1st radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference
-
Operating Current Rating Per Function In Amps
2.0 5th radio interference
-
Operating Current Rating Per Function In Amps
2.0 4th radio interference
-
Operating Current Rating Per Function In Amps
2.0 3rd radio interference
-
Operating Current Rating Per Function In Amps
2.0 2nd radio interference
-
Operating Current Rating Per Function In Amps
2.0 1st radio interference
-
Load Impedance Per Function
50.0 ohms 6th radio interference
-
Load Impedance Per Function
50.0 ohms 5th radio interference
-
Load Impedance Per Function
50.0 ohms 4th radio interference
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 5th radio interference
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
3.250 inches nominal
-
Body Length
4.000 inches nominal
-
Operating Voltage Rating And Type Per Function
28.0 volts dc 4th radio interference
-
Operating Voltage Rating And Type Per Function
28.0 volts dc 5th radio interference
-
Nominal Thread Size
0.164 inches
-
Style Designator
5 rectangular terminal/terminals on opposite surfaces
-
Body Width
3.000 inches nominal
-
Body Height
2.000 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.250 inches nominal
-
Operating Temp Range
-55.0 to 85.0 deg celsius
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 4th radio interference
-
Source Impedance Rating Per Function
50.0 ohms 6th radio interference
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Operating Current Rating Per Function In Amps
2.0 6th radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 3rd radio interference
-
Mounting Facility Screw Thread Series Designator
unc
-
Inclosure Type
encased
-
Mounting Facility Type And Quantity
4 threaded hole
-
Functional Terminal Type And Quantity
6 wire hook input
-
Functional Terminal Type And Quantity
6 wire hook output
-
Operating Voltage Rating And Type Per Function
28.0 volts dc 2nd radio interference
-
Operating Voltage Rating And Type Per Function
28.0 volts dc 3rd radio interference
-
Operating Voltage Rating And Type Per Function
28.0 volts dc 6th radio interference