NSN: 5915-00-008-2449
Filters and Networks
FILTER,BAND PASS
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Operating Temp Range
-20.0/+71.0 deg celsius
-
Discrimination At Specified Frequencies Per Function In Decibels
30.0 minimum 2nd band pass and 1.5 maximum 2nd band pass and 1.5 maximum 2nd band pass and 30.0 minimum 2nd band pass
-
Overall Height
0.695 inches nominal
-
Reference Frequency Per Function
494.075 single radio interference pulses per second
-
Unpackaged Unit Weight
42.000 grams
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 1st band pass
-
Body Width
1.120 inches maximum
-
Functional Terminal Type And Quantity
2 pin ground 3rd function
-
Source Impedance Rating Per Function
100.0 ohms 1st band pass
-
Reference Frequency Per Function
494.375 single radio interference two phase to two phase
-
Frequency Band Width Per Function
494.05 kilohertz 1st band pass and 494.10 kilohertz 1st band pass
-
Load Impedance Per Function
168.0 kilohms 1st band pass
-
Load Impedance Per Function
168.0 kilohms 2nd band pass
-
Frequency Band Width Per Function
494.35 kilohertz 2nd band pass and 494.40 kilohertz 2nd band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 2nd band pass
-
Source Impedance Rating Per Function
100.0 ohms 2nd band pass
-
Specified Frequencies Of Discrimination Per Function
493.275 kilohertz 1st band pass and 494.05 kilohertz 1st band pass and 494.10 kilohertz 1st band pass and 494.875 kilohertz 1st band pass
-
Inclosure Type
encased
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.235 inches minimum and 1.245 inches maximum
-
Functional Terminal Type And Quantity
1 pin input 1st function
-
Mounting Facility Type And Quantity
7 terminal
-
Body Height
0.595 inches maximum
-
Discrimination At Specified Frequencies Per Function In Decibels
30.0 minimum 1st band pass and 1.5 maximum 1st band pass and 1.5 maximum 1st band pass and 30.0 minimum 1st band pass
-
Vibration Resistance Range In Hertz
+10.0/+2000.0
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.840 inches minimum and 0.860 inches maximum
-
Body Material
metal
-
Specified Frequencies Of Discrimination Per Function
493.575 kilohertz 2nd band pass and 494.40 kilohertz 2nd band pass and 494.35 kilohertz 2nd band pass and 495.175 kilohertz 2nd band pass
-
Style Designator
rectangular terminal/terminals on one surface
-
Functional Terminal Type And Quantity
4 pin output 2nd function
-
Body Length
1.510 inches maximum