NSN: 5915-00-056-3284

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

5915 - Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Height

    1.000 inches nominal

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 blank

  • Full Load Insertion Loss Frequencies In Megahertz

    200.0 and 100.0 and 100.0 and 100.0 and 90.0 and 90.0

  • Functional Terminal Type And Quantity

    2 threaded stud output 2nd function

  • Maximum Voltage Drop Per Function

    0.5 volts ac 1st radio interference

  • Body Material

    metal

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Operating Voltage Rating And Type Per Function

    30.0 volts dc 2nd radio interference 2nd function

  • Operating Temp Range

    +0.0/+55.0 deg celsius

  • Style Designator

    rectangular terminal/terminals on opposite surfaces

  • Body Length

    4.000 inches nominal

  • Maximum Dielectric Withstanding Dc Voltage

    500.0 volts at sea level

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Vibration Resistance Range In Hertz

    +5.0/+55.0

  • Full Load Minimum Insertion Loss At Specified Frequency In Decibels

    75.0 and unc

  • Operating Voltage Rating And Type Per Function

    125.0 volts ac 1st radio interference 1st function

  • Mounting Facility Type And Quantity

    2 threaded stud

  • Nominal Thread Size

    0.164 inches

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    3.000 inches nominal

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Features Provided

    nut and shock resistant

  • Overall Height

    2.200 inches nominal

  • Body Width

    2.000 inches nominal

  • Inclosure Type

    hermetically sealed

  • Functional Terminal Type And Quantity

    2 threaded stud input 1st function

  • Full Load Insertion Loss Frequencies In Megahertz

    10.0 and 0.15 and 1.0 and 100.0 and 400.0

  • Special Features

    two filtered functions

  • Maximum Temp Rise

    20.0 deg celsius

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Maximum Voltage Drop Per Function

    0.5 volts dc 2nd radio interference

  • Operating Current Rating Per Function In Amps

    0.25 1st radio interference

  • Operating Current Rating Per Function In Amps

    0.25 2nd radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...