Technical Characteristics
-
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 1st radio interference
-
Mounting Facility Type And Quantity
16 unthreaded hole
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Operating Temp Range
-55.0/+85.0 deg celsius
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Operating Voltage Rating And Type Per Function
440.0 volts ac 1st radio interference 1st function
-
Unthreaded Mounting Hole Diameter
0.218 inches nominal
-
Inclosure Type
hermetically sealed
-
Functional Terminal Type And Quantity
3 threaded stud input 1st function
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Body Height
11.438 inches nominal
-
Special Features
electronic shielding gasket shall be supplied @with each filtor
-
Body Width
5.125 inches nominal
-
Principal Circuitry Type Per Function
inductance-capacitance 3rd radio interference
-
Functional Terminal Type And Quantity
3 threaded stud output 2nd function
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Operating Voltage Rating And Type Per Function
440.0 volts ac 3rd radio interference 3rd function
-
Style Designator
rectangular terminal/terminals on opposite surfaces
-
Operating Current Rating Per Function In Amps
50.0 3rd radio interference
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Operating Current Rating Per Function In Amps
50.0 2nd radio interference
-
Operating Current Rating Per Function In Amps
50.0 1st radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Body Material
metal
-
Overall Length
10.438 inches nominal
-
Body Length
8.000 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
4.625 inches nominal
-
Body Surface Treatment
tin
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 3rd radio interference
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
10.937 inches nominal
-
Power Line Frequency Rating Per Function In Hertz
400.0 2nd radio interference
-
Operating Voltage Rating And Type Per Function
440.0 volts ac 2nd radio interference 2nd function