NSN: 5915-00-078-3257
Filters and Networks
FILTER,BAND PASS-LOW PASS
FILTER,BAND PASS-LOW PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Frequency Band Width Per Function
1.00 hertz single low pass and 100.00 hertz single low pass
-
Body Width
1.560 inches nominal
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 single low pass
-
Reference Frequency Per Function
50.0 7th high pass any acceptable
-
Functional Terminal Type And Quantity
1 connector, plug input-output 3rd function
-
Input Impedance Per Function W/Load
50.0 ohms blank
-
Load Impedance Per Function
2.4 kilohms single band pass
-
Principal Circuitry Type Per Function
inductance-capacitance-resistance single band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
6.0 single band pass
-
Body Length
2.630 inches nominal
-
Load Impedance Per Function
2.4 kilohms single low pass
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 maximum single low pass and 50.0 minimum single low pass and 3.0 maximum single low pass and 50.0 minimum single low pass
-
Inclosure Type
encased
-
Overall Length
3.160 inches nominal
-
Functional Terminal Type And Quantity
1 standard tube base output 2nd function
-
Mounting Facility Type And Quantity
2 threaded hole
-
Body Height
1.870 inches nominal
-
Functional Terminal Type And Quantity
2 wire hook input 1st function
-
Body Material
metal
-
Frequency Band Width Per Function
1.575 kilohertz single band pass and 1.655 kilohertz single band pass
-
Principal Circuitry Type Per Function
inductance-capacitance single low pass
-
Source Impedance Rating Per Function
1.2 kilohms single band pass
-
Operating Temp Range
-55.0/+65.0 deg celsius
-
Mounting Facility Screw Thread Series Designator
unc
-
Specified Frequencies Of Discrimination Per Function
100.00 hertz single low pass and 2.00 kilohertz single low pass and 1.00 hertz single low pass and 4.00 kilohertz single low pass
-
Nominal Thread Size
0.138 inches
-
Reference Frequency Per Function
1.615 single radio interference any acceptable
-
Average Life Rating In Hours
10000.0
-
Vibration Resistance Range In Hertz
+10.0/+55.0
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.125 inches nominal
-
Style Designator
rectangular terminal/terminals on opposite surfaces
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.562 inches nominal
-
Source Impedance Rating Per Function
1.2 kilohms single low pass
-
Output Impedance Per Function W/Source Across Input
50.0 ohms blank