NSN: 5915-00-119-7331

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

5915 - Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Overall Length

    53.215 inches minimum and 55.225 inches maximum

  • Load Impedance Per Function

    50.0 ohms 5th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th radio interference

  • Inclosure Type

    hermetically sealed

  • Operating Voltage Rating And Type Per Function

    115.0 volts ac 5th radio interference 5th function

  • Operating Current Rating Per Function In Amps

    1.0 3rd radio interference

  • Load Impedance Per Function

    50.0 ohms 6th radio interference

  • Unpackaged Unit Weight

    3.000 pounds

  • Maximum Voltage Drop Per Function

    350.0 millivolts dc 6th radio interference

  • Input Terminal Identification

    ms3106e20-7p

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Maximum Voltage Drop Per Function

    1.0 volts ac 4th radio interference

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    3.860 inches minimum and 3.880 inches maximum

  • Maximum Voltage Drop Per Function

    1.0 volts ac 5th radio interference

  • Operating Current Rating Per Function In Amps

    1.0 6th radio interference

  • Operating Voltage Rating And Type Per Function

    115.0 volts ac 1st radio interference 1st function

  • Unthreaded Mounting Hole Diameter

    0.200 inches minimum and 0.220 inches maximum

  • Body Material

    metal

  • Source Impedance Rating Per Function

    50.0 ohms 5th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Body Length

    3.460 inches minimum and 3.470 inches maximum

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference

  • Operating Current Rating Per Function In Amps

    1.0 1st radio interference

  • Style Designator

    rectangular terminal/terminals on opposite surfaces

  • Source Impedance Rating Per Function

    50.0 ohms 6th radio interference

  • Functional Terminal Type And Quantity

    1 connector, plug output 2nd function

  • Output Terminal Manufacturer Code

    96906

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    2.730 inches minimum and 2.750 inches maximum

  • Operating Temp Range

    -65.0/+165.0 deg fahrenheit

  • Operating Voltage Rating And Type Per Function

    115.0 volts ac 2nd radio interference 2nd function

  • Load Impedance Per Function

    50.0 ohms 4th radio interference

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd radio interference

  • Operating Current Rating Per Function In Amps

    1.0 2nd radio interference

  • Operating Voltage Rating And Type Per Function

    28.0 volts dc 6th radio interference 6th function

  • Maximum Voltage Drop Per Function

    1.0 volts ac 1st radio interference

  • Operating Voltage Rating And Type Per Function

    115.0 volts ac 3rd radio interference 3rd function

  • Functional Terminal Type And Quantity

    1 connector, plug input 1st function

  • Maximum Dielectric Withstanding Ac Rms Voltage

    230.0 volts at sea level

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Operating Voltage Rating And Type Per Function

    115.0 volts ac 4th radio interference 4th function

  • Principal Circuitry Type Per Function

    inductance-capacitance 5th radio interference

  • Maximum Voltage Drop Per Function

    1.0 volts ac 2nd radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference

  • Special Features

    six filtered functions

  • Operating Current Rating Per Function In Amps

    1.0 4th radio interference

  • Maximum Dielectric Withstanding Dc Voltage

    56.0 volts at sea level

  • Power Line Frequency Rating Per Function In Hertz

    400.0 1st radio interference

  • Body Height

    3.170 inches minimum and 3.180 inches maximum

  • Output Terminal Identification

    ms3106e20-7p

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

  • Body Width

    2.930 inches minimum and 2.970 inches maximum

  • Power Line Frequency Rating Per Function In Hertz

    400.0 2nd radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 6th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 3rd radio interference

  • Operating Current Rating Per Function In Amps

    1.0 5th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 4th radio interference

  • Maximum Voltage Drop Per Function

    1.0 volts ac 3rd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 5th radio interference

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...