NSN: 5915-00-156-0088

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

5915 - Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Inclosure Type

    encased

  • Input Terminal Identification

    ms3112e128p

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • Body Surface Treatment

    tin

  • Vibration Resistance Range In Hertz

    +10.0/+2000.0

  • Overall Length

    3.938 inches nominal

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Source Impedance Rating Per Function

    50.0 ohms 5th radio interference

  • Functional Terminal Type And Quantity

    1 connector, receptacle input 1st function

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Maximum Voltage Drop Per Function

    4.0 volts ac 1st radio interference

  • Maximum Voltage Drop Per Function

    1.5 volts ac 3rd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    420.0 1st radio interference

  • Operating Current Rating Per Function In Amps

    0.05 3rd radio interference

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference

  • Operating Current Rating Per Function In Amps

    0.05 4th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    420.0 2nd radio interference

  • Body Width

    1.375 inches nominal

  • Operating Current Rating Per Function In Amps

    0.05 5th radio interference

  • Maximum Voltage Drop Per Function

    4.0 volts ac 2nd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    420.0 3rd radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

  • Operating Voltage Rating And Type Per Function

    132.0 volts ac 5th radio interference 5th function

  • Functional Terminal Type And Quantity

    5 turret output 2nd function

  • Operating Temp Range

    -54.0/+90.0 deg celsius

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 5th radio interference

  • Operating Voltage Rating And Type Per Function

    132.0 volts ac 4th radio interference 4th function

  • Functional Terminal Type And Quantity

    1 turret ground 3rd function

  • Operating Voltage Rating And Type Per Function

    132.0 volts ac 3rd radio interference 3rd function

  • Operating Current Rating Per Function In Amps

    5.0 2nd radio interference

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Operating Voltage Rating And Type Per Function

    132.0 volts ac 2nd radio interference 2nd function

  • Operating Voltage Rating And Type Per Function

    132.0 volts ac 2nd radio interference 1st function

  • Overall Height

    2.876 inches nominal

  • Mounting Facility Type And Quantity

    2 slot

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th radio interference

  • Load Impedance Per Function

    50.0 ohms 5th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Operating Current Rating Per Function In Amps

    5.0 1st radio interference

  • Mounting Slot Width

    0.140 inches nominal

  • Input Terminal Manufacturer Code

    96906

  • Nominal Thread Size

    0.112 inches

  • Mounting Facility Screw Thread Series Designator

    unc

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd radio interference

  • Special Features

    one ground function

  • Load Impedance Per Function

    50.0 ohms 4th radio interference

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.000 inches nominal

  • Style Designator

    rectangular terminal/terminals on two surfaces

  • Body Length

    3.500 inches nominal

  • Maximum Voltage Drop Per Function

    1.5 volts ac 5th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    420.0 5th radio interference

  • Maximum Voltage Drop Per Function

    1.5 volts ac 4th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    420.0 4th radio interference

  • Body Height

    2.000 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...