NSN: 5915-00-241-9333
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Length
5.250 inches nominal
-
Body Width
2.970 inches nominal
-
Body Height
1.370 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
3.250 inches nominal
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz
60.0 1st radio interference
-
Operating Current Rating Per Function In Amps
2.0 2nd radio interference
-
Iii Input Terminal Manufacturer Code
71468
-
Iii Input Terminal Identification
gs02-14s-7p-001
-
Iii Output Terminal Identification
gs02-14s-7s-001
-
Inclosure Type
encased
-
Mounting Facility Type And Quantity
4 threaded hole
-
Functional Terminal Type And Quantity
2 connector, receptacle output
-
Iii Maximum Dielectric Withstanding Ac Rms Voltage
500.0 volts at sea level
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 2nd radio interference
-
Nominal Thread Size
0.112 inches
-
Iii Body Surface Treatment
tin
-
Style Designator
2 rectangular terminal/terminals on one surface
-
Overall Height
1.570 inches nominal
-
Iii Vibration Resistance Range In Hertz
10.0 to 55.0
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
2.375 inches nominal
-
Iii Operating Temp Range
-65.0 to 100.0 deg celsius
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 2nd radio interference
-
Operating Current Rating Per Function In Amps
3.0 1st radio interference
-
Iii Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference
-
Iii Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Iii Output Terminal Manufacturer Code
71468
-
Mounting Facility Screw Thread Series Designator
unc
-
Mounting Facility Type And Quantity
3 threaded stud
-
Functional Terminal Type And Quantity
2 connector, receptacle input
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 1st radio interference
-
Iii Body Material
metal