NSN: 5915-00-304-8195
Filters and Networks
FILTER,BAND PASS
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Voltage Standing Wave Ratio Frequency Limits Per Function
54.0 hercules no.5599.1 two phase to two phase and 66.0 hercules no.5599.1 two phase to two phase
-
Inclosure Type
encased
-
Unthreaded Mounting Hole Diameter
0.136 inches nominal
-
Output Terminal Identification
12819female
-
Reference Frequency Per Function
60.0 hercules no.5599.1 pulses per second
-
Output Terminal Manufacturer Code
92755
-
Reference Frequency Per Function
60.0 hercules no.5599.1 two phase to two phase
-
Voltage Standing Wave Ratio Per Function
1.5 1st band pass
-
Overall Length
4.250 inches nominal
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 maximum 2nd band pass and 60.0 minimum 2nd band pass and 3.0 maximum 2nd band pass and 60.0 minimum 2nd band pass
-
Functional Terminal Type And Quantity
1 connector, receptacle input 1st function
-
Voltage Standing Wave Ratio Per Function
1.5 2nd band pass
-
Input Terminal Manufacturer Code
92755
-
Style Designator
rectangular terminal/terminals on opposite surfaces
-
Specified Frequencies Of Discrimination Per Function
66.00 megahertz 1st band pass and 27.50 megahertz 1st band pass and 54.00 megahertz 1st band pass and 92.50 megahertz 1st band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
2.0 1st band pass
-
Mounting Facility Type And Quantity
2 unthreaded hole
-
Insertion Loss At Reference Frequency Per Function In Decibels
2.0 2nd band pass
-
Input Terminal Identification
12819female
-
Overall Height
0.650 inches maximum
-
Discrimination At Specified Frequencies Per Function In Decibels
60.0 minimum 1st band pass and 3.0 maximum 1st band pass and 3.0 maximum 1st band pass and 60.0 minimum 1st band pass
-
Voltage Standing Wave Ratio Frequency Limits Per Function
54.0 hercules no.5599.1 pulses per second and 66.0 hercules no.5599.1 pulses per second
-
Frequency Band Width Per Function
54.00 megahertz 1st band pass and 66.00 megahertz 1st band pass
-
Functional Terminal Type And Quantity
1 connector, receptacle output 2nd function
-
Specified Frequencies Of Discrimination Per Function
54.00 megahertz 2nd band pass and 27.50 megahertz 2nd band pass and 66.00 megahertz 2nd band pass and 92.50 megahertz 2nd band pass
-
Body Width
1.500 inches nominal
-
Frequency Band Width Per Function
54.00 megahertz 2nd band pass and 66.00 megahertz 2nd band pass
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
3.750 inches nominal