NSN: 5915-00-409-0112

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

5915 - Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Mounting Facility Screw Thread Series Designator

    unc

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.500 inches nominal

  • Functional Terminal Type And Quantity

    2 turret ground 3rd function

  • Maximum Voltage Drop Per Function

    1.0 volts ac 1st radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.625 inches nominal

  • Inclosure Type

    hermetically sealed

  • Functional Terminal Type And Quantity

    2 tab, solder lug output 2nd function

  • Mounting Facility Type And Quantity

    1 threaded hole

  • Power Line Frequency Rating Per Function In Hertz

    400.0 2nd radio interference

  • Body Length

    3.000 inches maximum

  • Body Width

    2.130 inches maximum

  • Style Designator

    rectangular terminal/terminals on opposite surfaces

  • Vibration Resistance Range In Hertz

    +10.0/+500.0

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Operating Voltage Rating And Type Per Function

    115.0 volts ac 2nd radio interference 2nd function

  • Nominal Thread Size

    0.138 inches

  • Functional Terminal Type And Quantity

    2 tab, solder lug input 1st function

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Maximum Voltage Drop Per Function

    1.0 volts ac 2nd radio interference

  • Overall Height

    2.380 inches maximum

  • Power Line Frequency Rating Per Function In Hertz

    400.0 1st radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

  • Body Height

    1.500 inches maximum

  • Operating Temp Range

    -55.0/+95.0 deg celsius

  • Operating Current Rating Per Function In Amps

    3.5 2nd radio interference

  • Operating Voltage Rating And Type Per Function

    115.0 volts ac 1st radio interference 1st function

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Operating Current Rating Per Function In Amps

    3.5 1st radio interference

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...