NSN: 5915-00-410-5384
Filters and Networks
FILTER,BAND PASS
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Specified Frequencies Of Discrimination Per Function
3.02 megahertz 2nd band pass and 2.92 megahertz 2nd band pass and 2.96 megahertz 2nd band pass and 3.07 megahertz 2nd band pass
-
Frequency Band Width Per Function
0.08 megahertz 2nd band pass and 3.01 megahertz 2nd band pass
-
Functional Terminal Type And Quantity
1 pin input 1st function
-
Body Height
0.750 inches maximum
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 nominal 1st band pass and 3.0 nominal 1st band pass and 40.0 minimum 1st band pass and 40.0 minimum 1st band pass
-
Body Material
metal
-
Source Impedance Rating Per Function
10.0 ohms 1st band pass
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.500 inches nominal
-
Functional Terminal Type And Quantity
3 pin output 2nd function
-
Insertion Loss At Reference Frequency Per Function In Decibels
12.0 1st band pass
-
Style Designator
rectangular terminal/terminals on one surface
-
Source Impedance Rating Per Function
10.0 ohms 2nd band pass
-
Load Impedance Per Function
500.0 ohms 1st band pass
-
Overall Height
1.120 inches maximum
-
Insertion Loss At Reference Frequency Per Function In Decibels
12.0 2nd band pass
-
Specified Frequencies Of Discrimination Per Function
2.91 megahertz 1st band pass and 3.09 megahertz 1st band pass and 2.64 megahertz 1st band pass and 3.36 megahertz 1st band pass
-
Vibration Resistance Range In Hertz
+10.0/+500.0
-
Maximum Dielectric Withstanding Dc Voltage
500.0 volts at sea level
-
Reference Frequency Per Function
3.0 hercules no.5599.1 pulses per second
-
Body Width
3.020 inches maximum
-
Mounting Facility Screw Thread Series Designator
unc
-
Nominal Thread Size
0.112 inches
-
Operating Temp Range
-30.0/+85.0 deg celsius
-
Inclosure Type
hermetically sealed
-
Body Length
3.020 inches maximum
-
Input Impedance Per Function W/Load
300.0 ohms 1st band pass
-
Input Impedance Per Function W/Load
300.0 ohms 2nd band pass
-
Mounting Facility Type And Quantity
4 threaded stud
-
Frequency Band Width Per Function
2.91 megahertz 1st band pass and 3.09 megahertz 1st band pass
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
2.400 inches nominal
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 nominal 2nd band pass and 40.0 minimum 2nd band pass and 3.0 nominal 2nd band pass and 40.0 minimum 2nd band pass
-
Output Impedance Per Function W/Source Across Input
300.0 ohms 1st band pass
-
Load Impedance Per Function
500.0 ohms 2nd band pass
-
Output Impedance Per Function W/Source Across Input
300.0 ohms 2nd band pass
-
Functional Terminal Type And Quantity
1 pin ground 3rd function
-
Reference Frequency Per Function
3.0 hercules no.5599.1 two phase to two phase