NSN: 5915-00-421-2660
Filters and Networks
FILTER,BAND PASS
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Frequency Band Width Per Function
870.00 hertz 1st band pass and 1.275 kilohertz 1st band pass
-
Specified Frequencies Of Discrimination Per Function
50.00 kilohertz 2nd band pass and 61.50 kilohertz 2nd band pass and 75.50 kilohertz 2nd band pass and 104.00 kilohertz 2nd band pass
-
Specified Frequencies Of Discrimination Per Function
100.00 hertz 1st band pass and 870.00 hertz 1st band pass and 1.275 kilohertz 1st band pass and 2.75 kilohertz 1st band pass
-
Functional Terminal Type And Quantity
1 pin output
-
Functional Terminal Type And Quantity
1 pin ground
-
Mounting Facility Type And Quantity
4 threaded stud
-
Inclosure Type
encased
-
Principal Circuitry Type Per Function
inductance-resistance 2nd band pass
-
Principal Circuitry Type Per Function
inductance-resistance 1st band pass
-
Output Impedance Per Function W/Source Across Input
15.0 kilohms 1st band pass
-
Input Impedance Per Function W/Load
2.5 kilohms 2nd band pass
-
Load Impedance Per Function
15.0 kilohms 2nd band pass
-
Load Impedance Per Function
15.0 kilohms 1st band pass
-
Source Impedance Rating Per Function
15.0 kilohms 2nd band pass
-
Functional Terminal Type And Quantity
2 pin input
-
Insertion Loss At Reference Frequency Per Function In Decibels
6.0 2nd band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
6.0 1st band pass
-
Mounting Facility Screw Thread Series Designator
unc
-
Output Impedance Per Function W/Source Across Input
15.0 kilohms 2nd band pass
-
Input Impedance Per Function W/Load
2.5 kilohms 1st band pass
-
Reference Frequency Per Function
1.0 kilohertz 1st band pass
-
Operating Temp Range
-29.0 to 85.0 deg celsius
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.125 inches nominal
-
Body Length
3.000 inches maximum
-
Overall Height
2.380 inches nominal
-
Style Designator
2 rectangular terminal/terminals on one surface
-
Discrimination At Specified Frequencies Per Function In Decibels
40.0 nominal 2nd band pass and 3.0 nominal 2nd band pass and 3.0 nominal 2nd band pass and 40.0 nominal 2nd band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
40.0 nominal 1st band pass and 3.0 nominal 1st band pass and 3.0 nominal 1st band pass and 40.0 nominal 1st band pass
-
Frequency Band Width Per Function
61.50 kilohertz 2nd band pass and 75.50 kilohertz 2nd band pass
-
Nominal Thread Size
0.138 inches
-
Source Impedance Rating Per Function
15.0 kilohms 1st band pass
-
Reference Frequency Per Function
68.0 kilohertz 2nd band pass
-
Vibration Resistance Range In Hertz
10.0 to 55.0
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.250 inches nominal
-
Body Height
2.000 inches maximum
-
Body Width
1.630 inches maximum