NSN: 5915-00-471-9955

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

5915 - Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Mounting Facility Type And Quantity

    4 slot

  • Power Line Frequency Rating Per Function In Hertz

    400.0 2nd radio interference

  • Overall Height

    0.870 inches maximum

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference

  • Functional Terminal Type And Quantity

    4 tab, solder lug input 1st function

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • Maximum Dielectric Withstanding Dc Voltage

    150.0 volts at sea level

  • Vibration Resistance Range In Hertz

    +10.0/+2000.0

  • Operating Current Rating Per Function In Amps

    3.0 2nd radio interference

  • Operating Temp Range

    -55.0/+95.0 deg celsius

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference

  • Style Designator

    rectangular terminal/terminals on opposite surfaces

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.750 inches nominal

  • Operating Voltage Rating And Type Per Function

    250.0 volts ac 1st radio interference 1st function

  • Overall Width

    2.000 inches maximum

  • Load Impedance Per Function

    50.0 ohms 4th radio interference

  • Mounting Slot Width

    0.140 inches nominal

  • Operating Voltage Rating And Type Per Function

    100.0 volts dc 3rd radio interference 3rd function

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Maximum Voltage Drop Per Function

    0.9 millivolts ac 1st radio interference

  • Operating Voltage Rating And Type Per Function

    100.0 volts dc 4th radio interference 4th function

  • Body Width

    2.000 inches nominal

  • Inclosure Type

    hermetically sealed

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Maximum Voltage Drop Per Function

    0.9 millivolts ac 2nd radio interference

  • Overall Length

    2.000 inches maximum

  • Operating Current Rating Per Function In Amps

    1.0 3rd radio interference

  • Operating Voltage Rating And Type Per Function

    250.0 volts ac 2nd radio interference 2nd function

  • Body Length

    1.500 inches nominal

  • Power Line Frequency Rating Per Function In Hertz

    400.0 1st radio interference

  • Operating Current Rating Per Function In Amps

    3.0 1st radio interference

  • Operating Current Rating Per Function In Amps

    1.0 4th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference

  • Functional Terminal Type And Quantity

    4 tab, solder lug output 2nd function

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.500 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...