NSN: 5915-00-532-0768
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Overall Height
3.000 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.000 inches nominal
-
Iii Operating Temp Range
-55.0 to 85.0 deg celsius
-
Iii Average Life Rating In Hours
10000.0
-
Source Impedance Rating Per Function
5.0 ohms 2nd radio interference
-
Load Impedance Per Function
5.0 ohms 1st radio interference
-
Power Line Frequency Rating Per Function In Hertz
440.0 2nd radio interference
-
Operating Current Rating Per Function In Amps
2.0 2nd radio interference
-
Maximum Voltage Drop Per Function
2.4 volts ac 2nd radio interference
-
Iii Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference
-
Iii Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Iii Maximum Temp Rise
25.0 deg celsius
-
Inclosure Type
hermetically sealed
-
Functional Terminal Type And Quantity
2 wire lead output
-
Iii Maximum Dielectric Withstanding Ac Rms Voltage
250.0 volts at sea level
-
Style Designator
30 rectangular terminal/terminals on opposite surfaces
-
Overall Length
5.000 inches nominal
-
Body Length
3.000 inches nominal
-
Body Width
1.300 inches nominal
-
Unthreaded Mounting Hole Diameter
0.218 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.000 inches nominal
-
Source Impedance Rating Per Function
5.0 ohms 1st radio interference
-
Load Impedance Per Function
5.0 ohms 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz
440.0 1st radio interference
-
Operating Current Rating Per Function In Amps
2.0 1st radio interference
-
Maximum Voltage Drop Per Function
2.4 volts ac 1st radio interference
-
Mounting Facility Type And Quantity
4 unthreaded hole
-
Functional Terminal Type And Quantity
1 threaded stud ground
-
Functional Terminal Type And Quantity
2 wire lead input
-
Operating Voltage Rating And Type Per Function
130.0 volts ac 1st radio interference
-
Operating Voltage Rating And Type Per Function
130.0 volts ac 2nd radio interference
-
Iii Body Material
metal