NSN: 5915-00-613-0117
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Operating Current Rating Per Function In Amps
0.04 2nd radio interference
-
Operating Current Rating Per Function In Amps
0.04 3rd radio interference
-
Overall Length
4.406 inches nominal
-
Overall Height
1.250 inches nominal
-
Overall Width
2.375 inches nominal
-
Unthreaded Mounting Hole Diameter
0.156 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.016 inches nominal
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 4th radio interference
-
Source Impedance Rating Per Function
50.0 ohms 5th radio interference
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Load Impedance Per Function
50.0 ohms 5th radio interference
-
Operating Current Rating Per Function In Amps
0.04 5th radio interference
-
Mounting Facility Type And Quantity
2 unthreaded hole
-
Functional Terminal Type And Quantity
7 tab, solder lug input
-
Functional Terminal Type And Quantity
7 tab, solder lug output
-
Operating Voltage Rating And Type Per Function
150.0 volts dc 2nd radio interference
-
Operating Voltage Rating And Type Per Function
150.0 volts dc 6th radio interference
-
Operating Voltage Rating And Type Per Function
400.0 volts dc 4th radio interference
-
Body Material
metal
-
Operating Current Rating Per Function In Amps
0.04 1st radio interference
-
Body Length
2.906 inches nominal
-
Body Width
1.303 inches nominal
-
Operating Temp Range
-55.0 to 105.0 deg celsius
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Source Impedance Rating Per Function
50.0 ohms 6th radio interference
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Load Impedance Per Function
50.0 ohms 4th radio interference
-
Load Impedance Per Function
50.0 ohms 6th radio interference
-
Operating Current Rating Per Function In Amps
0.04 4th radio interference
-
Operating Current Rating Per Function In Amps
2.0 6th radio interference
-
Inclosure Type
hermetically sealed
-
Operating Voltage Rating And Type Per Function
150.0 volts dc 1st radio interference
-
Operating Voltage Rating And Type Per Function
400.0 volts dc 3rd radio interference
-
Operating Voltage Rating And Type Per Function
400.0 volts dc 5th radio interference
-
Style Designator
1 rectangular terminal/terminals on opposite surfaces