NSN: 5915-00-772-6039
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Length
1.700 inches maximum
-
Body Height
1.030 inches nominal
-
Vibration Resistance Range In Hertz
p10.0/p500.0
-
Average Life Rating In Hours
2500.0
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Load Impedance Per Function
50.0 ohms 4th radio interference
-
Power Line Frequency Rating Per Function In Hertz
360.0 2nd radio interference
-
Operating Current Rating Per Function In Amps
0.1 5th radio interference
-
Operating Current Rating Per Function In Amps
0.2 1st radio interference
-
Operating Current Rating Per Function In Amps
5.0 4th radio interference
-
Operating Current Rating Per Function In Amps
6.0 3rd radio interference
-
Maximum Voltage Drop Per Function
0.1 volts dc 1st radio interference
-
Maximum Voltage Drop Per Function
0.1 volts dc 5th radio interference
-
Inclosure Type
hermetically sealed
-
Mounting Facility Type And Quantity
10 terminal
-
Operating Voltage Rating And Type Per Function
100.0 volts dc 5th radio interference
-
Operating Voltage Rating And Type Per Function
6.3 volts ac 4th radio interference and 100.0 volts dc 4th radio interference
-
Overall Length
1.820 inches nominal
-
Overall Height
1.562 inches maximum
-
Body Width
0.640 inches maximum
-
Operating Temp Range
m54.0/p85.0 deg celsius
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 4th radio interference
-
Source Impedance Rating Per Function
50.0 ohms 5th radio interference
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Load Impedance Per Function
50.0 ohms 5th radio interference
-
Power Line Frequency Rating Per Function In Hertz
360.0 4th radio interference
-
Operating Current Rating Per Function In Amps
1.0 2nd radio interference
-
Maximum Voltage Drop Per Function
0.03 volts ac 4th radio interference and 0.03 volts dc 4th radio interference
-
Maximum Voltage Drop Per Function
0.1 volts ac 2nd radio interference and 0.1 volts dc 2nd radio interference
-
Maximum Voltage Drop Per Function
0.1 volts dc 3rd radio interference
-
Maximum Temp Rise
20.0 deg celsius
-
Functional Terminal Type And Quantity
5 tab,solder lug input
-
Functional Terminal Type And Quantity
5 tab,solder lug output
-
Operating Voltage Rating And Type Per Function
100.0 volts dc 3rd radio interference
-
Operating Voltage Rating And Type Per Function
125.0 volts ac 2nd radio interference and 400.0 volts dc 2nd radio interference
-
Operating Voltage Rating And Type Per Function
300.0 volts dc 1st radio interference
-
Body Material