NSN: 5915-00-833-5356
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference
-
Special Features
duty cycle 3 min on & 17 min off
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Overall Length
1.250 inches minimum
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Body Width
1.080 inches minimum and 1.100 inches maximum
-
Operating Current Rating Per Function In Amps
2.0 1st radio interference
-
Inclosure Type
hermetically sealed
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.930 inches minimum and 0.940 inches maximum
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Operating Voltage Rating And Type Per Function
100.0 volts dc 3rd radio interference 3rd function
-
Operating Voltage Rating And Type Per Function
100.0 volts dc 2nd radio interference 2nd function
-
Principal Circuitry Type Per Function
inductance-capacitance 3rd radio interference
-
Mounting Facility Type And Quantity
4 unthreaded hole
-
Unthreaded Mounting Hole Diameter
0.150 inches minimum and 0.155 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
0.975 inches minimum and 0.985 inches maximum
-
Operating Current Rating Per Function In Amps
2.0 3rd radio interference
-
Operating Voltage Rating And Type Per Function
100.0 volts dc 1st radio interference 1st function
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Style Designator
rectangular terminal/terminals on opposite surfaces
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Functional Terminal Type And Quantity
3 tab, solder lug output 2nd function
-
Body Length
1.205 inches minimum
-
Overall Height
1.160 inches minimum and 1.210 inches maximum
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Maximum Voltage Drop Per Function
270.0 millivolts dc 3rd radio interference
-
Body Material
metal
-
Maximum Voltage Drop Per Function
270.0 millivolts dc 2nd radio interference
-
Operating Current Rating Per Function In Amps
2.0 2nd radio interference
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Operating Temp Range
-55.0/+125.0 deg celsius
-
Functional Terminal Type And Quantity
3 pin input 1st function
-
Maximum Voltage Drop Per Function
270.0 millivolts dc 1st radio interference
-
Overall Width
1.540 inches maximum