NSN: 5915-00-847-2350
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Operating Current Rating Per Function In Amps
0.5 6th radio interference
-
Operating Voltage Rating And Type Per Function
400.0 volts dc 6th radio interference 6th function
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Unthreaded Mounting Hole Diameter
0.187 inches nominal
-
Overall Height
1.094 inches nominal
-
Inclosure Type
encased
-
Source Impedance Rating Per Function
50.0 ohms 4th radio interference
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Body Material
metal
-
Source Impedance Rating Per Function
50.0 ohms 5th radio interference
-
Style Designator
rectangular terminal/terminals on one surface
-
Functional Terminal Type And Quantity
6 tab, solder lug input 1st function
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 6th radio interference
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
3.688 inches nominal
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Operating Voltage Rating And Type Per Function
400.0 volts dc 1st radio interference 1st function
-
Load Impedance Per Function
50.0 ohms 4th radio interference
-
Mounting Facility Type And Quantity
4 unthreaded hole
-
Body Height
0.688 inches nominal
-
Body Width
1.125 inches nominal
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Load Impedance Per Function
50.0 ohms 5th radio interference
-
Operating Voltage Rating And Type Per Function
400.0 volts dc 2nd radio interference 2nd function
-
Operating Current Rating Per Function In Amps
0.5 1st radio interference
-
Functional Terminal Type And Quantity
6 tab, solder lug output 2nd function
-
Body Length
4.062 inches nominal
-
Operating Voltage Rating And Type Per Function
400.0 volts dc 3rd radio interference 3rd function
-
Operating Current Rating Per Function In Amps
0.5 2nd radio interference
-
Operating Voltage Rating And Type Per Function
400.0 volts dc 4th radio interference 4th function
-
Load Impedance Per Function
50.0 ohms 6th radio interference
-
Operating Current Rating Per Function In Amps
0.5 3rd radio interference
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.625 inches nominal
-
Operating Current Rating Per Function In Amps
0.5 4th radio interference
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Operating Voltage Rating And Type Per Function
400.0 volts dc 5th radio interference 5th function
-
Operating Current Rating Per Function In Amps
0.5 5th radio interference