NSN: 5915-00-921-3829
Filters and Networks
FILTER,BAND PASS
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Principal Circuitry Type Per Function
inductance-capacitance 1st band pass
-
Maximum Dielectric Withstanding Ac Rms Voltage
500.0 volts at sea level
-
Inclosure Type
hermetically sealed
-
Body Width
1.410 inches maximum
-
Frequency Band Width Per Function
892.50 hertz 1st band pass and 977.50 hertz 1st band pass
-
Special Features
two filtered functions
-
Load Impedance Per Function
600.0 ohms 2nd band pass
-
Source Impedance Rating Per Function
600.0 ohms 2nd band pass
-
Functional Terminal Type And Quantity
1 turret ground 3rd function
-
Frequency Band Width Per Function
892.50 hertz 2nd band pass and 977.50 hertz 2nd band pass
-
Reference Frequency Per Function
935.0 single high pass pulses per second
-
Style Designator
rectangular terminal/terminals on one surface
-
Insertion Loss At Reference Frequency Per Function In Decibels
2.5 1st band pass
-
Body Height
3.250 inches nominal
-
Insertion Loss At Reference Frequency Per Function In Decibels
2.5 2nd band pass
-
Vibration Resistance Range In Hertz
+10.0/+55.0
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 minimum 2nd band pass and 45.0 maximum 2nd band pass
-
Average Life Rating In Hours
10000.0
-
Nominal Thread Size
0.138 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.375 inches nominal
-
Mounting Facility Type And Quantity
2 threaded stud
-
Mounting Facility Screw Thread Series Designator
unc
-
Functional Terminal Type And Quantity
2 turret input 1st function
-
Load Impedance Per Function
600.0 ohms 1st band pass
-
Operating Temp Range
+0.0/+60.0 deg celsius
-
Source Impedance Rating Per Function
600.0 ohms 1st band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 minimum 1st band pass and 45.0 maximum 1st band pass
-
Functional Terminal Type And Quantity
2 turret output 2nd function
-
Overall Height
3.525 inches nominal
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd band pass
-
Reference Frequency Per Function
935.0 single high pass two phase to two phase
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.938 inches nominal
-
Body Length
4.980 inches nominal
-
Mounting Facility Type And Quantity
4 threaded hole
-
Body Material
metal