NSN: 5915-00-921-4505
Filters and Networks
FILTER,BAND PASS
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 minimum 3rd band pass and 30.0 maximum 3rd band pass
-
Reference Frequency Per Function
1.445 single radio interference two phase to three phase
-
Special Features
electrostatic shield brought out to terminal six
-
Load Impedance Per Function
600.0 ohms 3rd band pass
-
Source Impedance Rating Per Function
600.0 ohms 3rd band pass
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd band pass
-
Reference Frequency Per Function
1.445 single radio interference two phase to two phase
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 3rd band pass
-
Body Height
2.950 inches nominal
-
Mounting Facility Type And Quantity
4 threaded hole
-
Body Material
metal
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 minimum 2nd band pass and 30.0 maximum 2nd band pass
-
Specified Frequencies Of Discrimination Per Function
1.4025 kilohertz 1st band pass and 1.42375 kilohertz 1st band pass and 1.46625 kilohertz 1st band pass and 1.4875 kilohertz 1st band pass
-
Style Designator
rectangular terminal/terminals on one surface
-
Operating Temp Range
-55.0/+65.0 deg celsius
-
Principal Circuitry Type Per Function
inductance-capacitance 3rd band pass
-
Specified Frequencies Of Discrimination Per Function
1.46625 kilohertz 2nd band pass and 1.4025 kilohertz 2nd band pass and 1.42375 kilohertz 2nd band pass and 1.4875 kilohertz 2nd band pass
-
Vibration Resistance Range In Hertz
+10.0/+500.0
-
Maximum Dielectric Withstanding Dc Voltage
500.0 volts at sea level
-
Body Length
3.000 inches nominal
-
Average Life Rating In Hours
10000.0
-
Frequency Band Width Per Function
1.42375 kilohertz 1st band pass and 1.46625 kilohertz 1st band pass
-
Nominal Thread Size
0.138 inches
-
Mounting Facility Type And Quantity
2 threaded stud
-
Features Provided
electrostatic shield
-
Mounting Facility Screw Thread Series Designator
unc
-
Functional Terminal Type And Quantity
2 turret input 1st function
-
Load Impedance Per Function
600.0 ohms 1st band pass
-
Frequency Band Width Per Function
1.42375 kilohertz 2nd band pass and 1.46625 kilohertz 2nd band pass
-
Source Impedance Rating Per Function
600.0 ohms 1st band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 2nd band pass
-
Functional Terminal Type And Quantity
1 turret ground 3rd function
-
Source Impedance Rating Per Function
600.0 ohms 2nd band pass
-
Load Impedance Per Function
600.0 ohms 2nd band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 minimum 1st band pass and 30.0 maximum 1st band pass
-
Functional Terminal Type And Quantity
3 turret output 2nd function
-
Reference Frequency Per Function
1.445 single radio interference pulses per second
-
Specified Frequencies Of Discrimination Per Function
1.46625 kilohertz 3rd band pass and 1.4025 kilohertz 3rd band pass and 1.42375 kilohertz 3rd band pass and 1.4875 kilohertz 3rd band pass
-
Overall Height
3.230 inches nominal
-
Body Width
1.410 inches maximum
-
Inclosure Type
hermetically sealed
-
Frequency Band Width Per Function
1.42375 kilohertz 3rd band pass and 1.46625 kilohertz 3rd band pass
-
Principal Circuitry Type Per Function
inductance-capacitance 1st band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 1st band pass