NSN: 5915-00-924-1887

Filters and Networks

FILTER,BAND PASS

5915 - Filters and Networks

FILTER,BAND PASS

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Input Impedance Per Function W/Load

    4.0 kilohms 4th band pass

  • Reference Frequency Per Function

    266.0 single high pass three phase to two phase

  • Input Impedance Per Function W/Load

    4.0 kilohms 5th band pass

  • Reference Frequency Per Function

    266.0 single high pass two phase to three phase

  • Discrimination At Specified Frequencies Per Function In Decibels

    3.0 maximum 4th band pass and 45.0 minimum 4th band pass and 3.0 maximum 4th band pass and 45.0 minimum 4th band pass

  • Reference Frequency Per Function

    266.0 single high pass two phase to two phase

  • Insertion Loss At Reference Frequency Per Function In Decibels

    5.0 5th band pass

  • Input Impedance Per Function W/Load

    4.0 kilohms 1st band pass

  • Body Width

    1.750 inches maximum

  • Frequency Band Width Per Function

    200.00 hertz 1st band pass and 332.00 hertz 1st band pass

  • Specified Frequencies Of Discrimination Per Function

    200.00 hertz 4th band pass and 150.00 hertz 4th band pass and 332.00 hertz 4th band pass and 392.00 hertz 4th band pass

  • Functional Terminal Type And Quantity

    2 wire lead input 1st function

  • Discrimination At Specified Frequencies Per Function In Decibels

    45.0 minimum 2nd band pass and 3.0 maximum 2nd band pass and 3.0 maximum 2nd band pass and 45.0 minimum 2nd band pass

  • Overall Height

    0.400 inches maximum

  • Specified Frequencies Of Discrimination Per Function

    200.00 hertz 5th band pass and 332.00 hertz 5th band pass and 150.00 hertz 5th band pass and 392.00 hertz 5th band pass

  • Operating Temp Range

    -20.0/+80.0 deg celsius

  • Input Impedance Per Function W/Load

    4.0 kilohms 2nd band pass

  • Reference Frequency Per Function

    266.0 single high pass hertz

  • Body Length

    2.000 inches maximum

  • Frequency Band Width Per Function

    200.00 hertz 2nd band pass and 332.00 hertz 2nd band pass

  • Reference Frequency Per Function

    266.0 single high pass pulses per second

  • Input Impedance Per Function W/Load

    4.0 kilohms 3rd band pass

  • Specified Frequencies Of Discrimination Per Function

    332.00 hertz 1st band pass and 150.00 hertz 1st band pass and 200.00 hertz 1st band pass and 392.00 hertz 1st band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    3.0 maximum 3rd band pass and 45.0 minimum 3rd band pass and 3.0 maximum 3rd band pass and 45.0 minimum 2nd band pass

  • Output Impedance Per Function W/Source Across Input

    10.0 kilohms 2nd band pass

  • Frequency Band Width Per Function

    200.00 hertz 4th band pass and 332.00 hertz 4th band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    3.0 maximum 5th band pass and 3.0 maximum 5th band pass and 45.0 minimum 5th band pass and 45.0 minimum 5th band pass

  • Frequency Band Width Per Function

    200.00 hertz 5th band pass and 332.00 hertz 5th band pass

  • Functional Terminal Type And Quantity

    1 wire lead ground 3rd function

  • Insertion Loss At Reference Frequency Per Function In Decibels

    5.0 1st band pass

  • Body Material

    metal

  • Specified Frequencies Of Discrimination Per Function

    150.00 hertz 3rd band pass and 332.00 hertz 3rd band pass and 200.00 hertz 3rd band pass and 392.00 hertz 3rd band pass

  • Functional Terminal Type And Quantity

    2 wire lead output 2nd function

  • Output Impedance Per Function W/Source Across Input

    10.0 kilohms 3rd band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    5.0 2nd band pass

  • Style Designator

    rectangular terminal/terminals on one surface

  • Insertion Loss At Reference Frequency Per Function In Decibels

    5.0 3rd band pass

  • Output Impedance Per Function W/Source Across Input

    10.0 kilohms 4th band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    5.0 4th band pass

  • Output Impedance Per Function W/Source Across Input

    10.0 kilohms 5th band pass

  • Inclosure Type

    encased

  • Output Impedance Per Function W/Source Across Input

    10.0 kilohms 1st band pass

  • Frequency Band Width Per Function

    200.00 hertz 3rd band pass and 332.00 hertz 3rd band pass

  • Mounting Facility Type And Quantity

    5 terminal

  • Body Height

    0.775 inches nominal

  • Specified Frequencies Of Discrimination Per Function

    200.00 hertz 2nd band pass and 332.00 hertz 2nd band pass and 150.00 hertz 2nd band pass and 392.00 hertz 2nd band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    45.0 minimum 1st band pass and 3.0 maximum 1st band pass and 3.0 maximum 1st band pass and 45.0 minimum 1st band pass

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...