NSN: 5915-00-927-9880
Filters and Networks
FILTER,HIGH PASS
FILTER,HIGH PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Functional Terminal Type And Quantity
1 pin output 2nd function
-
Insertion Loss At Reference Frequency Per Function In Decibels
1.5 blank
-
Mounting Facility Type And Quantity
1 threaded stud
-
Reference Frequency Per Function
3.6 kilohertz blank
-
Body Width
1.500 inches nominal
-
Specified Frequencies Of Discrimination Per Function
485.00 hertz blank and 970.00 hertz blank and 1.02 kilohertz blank and 8.30 kilohertz blank
-
Overall Height
2.312 inches nominal
-
Source Impedance Rating Per Function
1.0 kilohms blank
-
Frequency Band Width Per Function
970.00 hertz blank and 8.30 kilohertz blank
-
Functional Terminal Type And Quantity
1 pin input 1st function
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.600 inches nominal
-
Reference Number Differentiating Characteristics
quality controlled and selected
-
Principal Circuitry Type Per Function
inductance-capacitance blank
-
Body Length
2.000 inches nominal
-
Load Impedance Per Function
1.0 kilohms blank
-
Style Designator
rectangular terminal/terminals on one surface
-
Body Height
2.000 inches nominal
-
Average Life Rating In Hours
10000.0
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.000 inches nominal
-
Nominal Thread Size
0.112 inches
-
Discrimination At Specified Frequencies Per Function In Decibels
0.5 nominal blank and 3.0 nominal blank and 65.0 nominal blank and 0.5 nominal blank
-
Operating Temp Range
+0.0/+60.0 deg celsius
-
Functional Terminal Type And Quantity
2 pin ground 3rd function
-
Inclosure Type
hermetically sealed