Technical Characteristics

  • Source Impedance Rating Per Function

    1.0 kilohms 4th band pass

  • Frequency Band Width Per Function

    922.00 hertz 4th band pass and 959.00 hertz 4th band pass

  • Specified Frequencies Of Discrimination Per Function

    785.00 hertz 2nd band pass and 755.00 hertz 2nd band pass and 747.00 hertz 2nd band pass and 794.00 hertz 2nd band pass

  • Source Impedance Rating Per Function

    1.0 kilohms 5th band pass

  • Load Impedance Per Function

    100.0 kilohms 1st band pass

  • Body Material

    metal

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 4th band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    3.0 minimum 2nd band pass and 30.0 maximum 2nd band pass

  • Reference Frequency Per Function

    941.0 single high pass hertz

  • Style Designator

    rectangular terminal/terminals on one surface

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    3.0 minimum 3rd band pass and 30.0 maximum 3rd band pass

  • Reference Frequency Per Function

    852.0 single high pass two phase to three phase

  • Discrimination At Specified Frequencies Per Function In Decibels

    3.0 minimum 4th band pass and 30.0 maximum 4th band pass

  • Body Width

    2.380 inches maximum

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd band pass

  • Frequency Band Width Per Function

    558.00 hertz 5th band pass and 582.00 hertz 5th band pass

  • Vibration Resistance Range In Hertz

    +10.0/+500.0

  • Reference Frequency Per Function

    770.0 single high pass two phase to two phase

  • Functional Terminal Type And Quantity

    1 pin input 1st function

  • Specified Frequencies Of Discrimination Per Function

    922.00 hertz 4th band pass and 959.00 hertz 4th band pass and 913.00 hertz 4th band pass and 970.00 hertz 4th band pass

  • Frequency Band Width Per Function

    755.00 hertz 2nd band pass and 785.00 hertz 2nd band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 3rd band pass

  • Body Surface Treatment

    tin

  • Operating Temp Range

    -18.0/+75.0 deg celsius

  • Average Life Rating In Hours

    26280.0

  • Load Impedance Per Function

    100.0 kilohms 2nd band pass

  • Specified Frequencies Of Discrimination Per Function

    676.00 hertz 1st band pass and 710.00 hertz 1st band pass and 684.00 hertz 1st band pass and 718.00 hertz 1st band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 5th band pass

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.750 inches nominal

  • Functional Terminal Type And Quantity

    1 pin ground 3rd function

  • Load Impedance Per Function

    100.0 kilohms 3rd band pass

  • Mounting Facility Type And Quantity

    14 pin

  • Load Impedance Per Function

    100.0 kilohms 4th band pass

  • Source Impedance Rating Per Function

    1.0 kilohms 1st band pass

  • Frequency Band Width Per Function

    684.00 hertz 1st band pass and 710.00 hertz 1st band pass

  • Specified Frequencies Of Discrimination Per Function

    558.00 hertz 5th band pass and 551.00 hertz 5th band pass and 582.00 hertz 5th band pass and 589.00 hertz 5th band pass

  • Load Impedance Per Function

    100.0 kilohms 5th band pass

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th band pass

  • Body Length

    4.030 inches maximum

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 1st band pass

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st band pass

  • Body Height

    0.510 inches maximum

  • Specified Frequencies Of Discrimination Per Function

    826.00 hertz 3rd band pass and 869.00 hertz 3rd band pass and 835.00 hertz 3rd band pass and 878.00 hertz 3rd band pass

  • Frequency Band Width Per Function

    835.00 hertz 3rd band pass and 869.00 hertz 3rd band pass

  • Functional Terminal Type And Quantity

    5 pin output 2nd function

  • Inclosure Type

    hermetically sealed

  • Unpackaged Unit Weight

    8.000 ounces

  • Source Impedance Rating Per Function

    1.0 kilohms 2nd band pass

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    3.500 inches nominal

  • Overall Height

    0.700 inches maximum

  • Principal Circuitry Type Per Function

    inductance-capacitance 5th band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    3.0 minimum 1st band pass and 30.0 maximum 1st band pass

  • Reference Frequency Per Function

    570.0 single high pass three phase to two phase

  • Discrimination At Specified Frequencies Per Function In Decibels

    3.0 minimum 5th band pass and 30.0 maximum 5th band pass

  • Source Impedance Rating Per Function

    1.0 kilohms 3rd band pass

  • Reference Frequency Per Function

    697.0 single high pass pulses per second

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 2nd band pass

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...