NSN: 5915-01-035-6811

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

5915 - Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Operating Voltage Rating And Type Per Function

    50.0 volts dc 4th radio interference 4th function

  • Operating Voltage Rating And Type Per Function

    50.0 volts dc 5th radio interference 5th function

  • Load Impedance Per Function

    50.0 ohms 4th radio interference

  • Output Terminal Identification

    ms3124-e18-11s

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Input Terminal Manufacturer Code

    96906

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Output Terminal Manufacturer Code

    96906

  • Operating Voltage Rating And Type Per Function

    50.0 volts dc 3rd radio interference 3rd function

  • Overall Length

    9.500 inches maximum

  • Style Designator

    rectangular terminal/terminals on opposite surfaces

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference

  • Operating Current Rating Per Function In Amps

    50.0 2nd radio interference

  • Operating Current Rating Per Function In Amps

    50.0 1st radio interference

  • Operating Voltage Rating And Type Per Function

    50.0 volts dc 2nd radio interference 2nd function

  • Maximum Voltage Drop Per Function

    500.0 millivolts dc 5th radio interference

  • Functional Terminal Type And Quantity

    1 connector, receptacle input 1st function

  • Source Impedance Rating Per Function

    50.0 ohms 5th radio interference

  • Body Material

    metal

  • Maximum Voltage Drop Per Function

    500.0 millivolts dc 4th radio interference

  • Body Length

    8.100 inches maximum

  • Maximum Voltage Drop Per Function

    500.0 millivolts dc 3rd radio interference

  • Body Width

    5.500 inches maximum

  • Maximum Voltage Drop Per Function

    500.0 millivolts dc 2nd radio interference

  • Input Terminal Identification

    ms3124-e20-16p

  • Operating Voltage Rating And Type Per Function

    50.0 volts dc 1st radio interference 1st function

  • Operating Current Rating Per Function In Amps

    5.0 3rd radio interference

  • Inclosure Type

    encased

  • Operating Current Rating Per Function In Amps

    5.0 4th radio interference

  • Operating Current Rating Per Function In Amps

    5.0 5th radio interference

  • Maximum Voltage Drop Per Function

    500.0 millivolts dc 1st radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference

  • Body Height

    3.000 inches maximum

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • Body Surface Treatment

    tin

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    8.760 inches maximum

  • Operating Temp Range

    +0.0/+60.0 deg celsius

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    3.500 inches maximum

  • Load Impedance Per Function

    50.0 ohms 5th radio interference

  • Unthreaded Mounting Hole Diameter

    0.218 inches nominal

  • Functional Terminal Type And Quantity

    2 connector, receptacle output 2nd function

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...