NSN: 5915-01-038-6192
Filters and Networks
FILTER,LOW PASS
FILTER,LOW PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.250 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
-
Mounting Facility Screw Thread Series Designator
unc
-
Insertion Loss At Reference Frequency Per Function In Decibels
2.0 2nd low pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
2.0 3rd low pass
-
Load Impedance Per Function
10.0 kilohms 1st low pass
-
Discrimination At Specified Frequencies Per Function In Decibels
6.0 maximum 3rd low pass and 50.0 minimum 3rd low pass and 6.0 maximum 3rd low pass and 60.0 minimum 3rd low pass
-
Frequency Band Width Per Function
1.00 hertz 2nd low pass and 55.00 hertz 2nd low pass
-
Load Impedance Per Function
10.0 kilohms 2nd low pass
-
Body Length
1.688 inches nominal
-
Body Width
1.188 inches nominal
-
Specified Frequencies Of Discrimination Per Function
187.00 hertz 3rd low pass and 1.00 hertz 3rd low pass and 110.00 hertz 3rd low pass and 374.00 hertz 3rd low pass
-
Load Impedance Per Function
10.0 kilohms 3rd low pass
-
Frequency Band Width Per Function
1.00 hertz 3rd low pass and 110.00 hertz 3rd low pass
-
Reference Frequency Per Function
28.0 7th high pass two phase to two phase
-
Source Impedance Rating Per Function
10.0 kilohms 1st low pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
2.0 1st low pass
-
Reference Frequency Per Function
55.5 7th high pass two phase to three phase
-
Nominal Thread Size
0.138 inches
-
Reference Frequency Per Function
69.5 7th high pass pulses per second
-
Discrimination At Specified Frequencies Per Function In Decibels
6.0 maximum 2nd low pass and 6.0 maximum 2nd low pass and 50.0 minimum 2nd low pass and 60.0 minimum 2nd low pass
-
Style Designator
rectangular terminal/terminals on one surface
-
Specified Frequencies Of Discrimination Per Function
132.00 hertz 2nd low pass and 1.00 hertz 2nd low pass and 55.00 hertz 2nd low pass and 264.00 hertz 2nd low pass
-
Mounting Facility Type And Quantity
2 threaded hole
-
Frequency Band Width Per Function
1.00 hertz 1st low pass and 138.00 hertz 1st low pass
-
Functional Terminal Type And Quantity
1 standard tube base input-output/ground
-
Source Impedance Rating Per Function
10.0 kilohms 3rd low pass
-
Body Height
3.125 inches nominal
-
Specified Frequencies Of Discrimination Per Function
138.00 hertz 1st low pass and 1.00 hertz 1st low pass and 215.00 hertz 1st low pass and 430.00 hertz 1st low pass
-
Source Impedance Rating Per Function
10.0 kilohms 2nd low pass
-
Inclosure Type
encased
-
Discrimination At Specified Frequencies Per Function In Decibels
50.0 minimum 1st low pass and 6.0 maximum 1st low pass and 6.0 maximum 1st low pass and 60.0 minimum 1st low pass