NSN: 5915-01-052-6906

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

5915 - Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference

  • Load Impedance Per Function

    50.0 ohms 4th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 2nd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 3rd radio interference

  • Overall Length

    9.900 inches nominal

  • Body Length

    6.900 inches nominal

  • Body Width

    4.700 inches nominal

  • Body Height

    3.500 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.205 inches nominal

  • Iii Operating Temp Range

    -55.0 to 85.0 deg celsius

  • Power Line Frequency Rating Per Function In Hertz

    400.0 4th radio interference

  • Maximum Voltage Drop Per Function

    2.5 volts ac 2nd radio interference and 6.0 volts dc 2nd radio interference

  • Functional Terminal Type And Quantity

    1 threaded stud input

  • Functional Terminal Type And Quantity

    1 threaded stud output

  • Operating Voltage Rating And Type Per Function

    250.0 volts ac 1st radio interference and 600.0 volts dc 1st radio interference

  • Operating Voltage Rating And Type Per Function

    250.0 volts ac 2nd radio interference and 600.0 volts dc 2nd radio interference

  • Operating Voltage Rating And Type Per Function

    250.0 volts ac 3rd radio interference and 600.0 volts dc 3rd radio interference

  • Iii Body Material

    metal

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 1st radio interference

  • Operating Current Rating Per Function In Amps

    50.0 1st radio interference

  • Operating Current Rating Per Function In Amps

    50.0 2nd radio interference

  • Operating Current Rating Per Function In Amps

    50.0 3rd radio interference

  • Operating Current Rating Per Function In Amps

    50.0 4th radio interference

  • Maximum Voltage Drop Per Function

    2.5 volts ac 1st radio interference and 6.0 volts dc 1st radio interference

  • Maximum Voltage Drop Per Function

    2.5 volts ac 3rd radio interference and 6.0 volts dc 3rd radio interference

  • Maximum Voltage Drop Per Function

    2.5 volts ac 4th radio interference and 6.0 volts dc 4th radio interference

  • Iii Maximum Temp Rise

    25.0 deg celsius

  • Inclosure Type

    hermetically sealed

  • Mounting Facility Type And Quantity

    6 unthreaded hole

  • Operating Voltage Rating And Type Per Function

    250.0 volts ac 4th radio interference and 600.0 volts dc 4th radio interference

  • Iii Maximum Dielectric Withstanding Dc Voltage

    1.2 kilovolts at sea level

  • Iii Body Surface Treatment

    tin

  • Style Designator

    5 rectangular terminal/terminals on opposite surfaces

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...