NSN: 5915-01-060-4894

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

5915 - Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 1st radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

  • Functional Terminal Type And Quantity

    12 tab w/screw output and 1 connector, receptacle input and 1 tab w/screw output-ground

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 4th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 5th radio interference

  • Vibration Resistance Range In Hertz

    +4.0/+33.0

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 6th radio interference

  • Style Designator

    rectangular terminal/terminals on adjacent surfaces

  • Overall Height

    2.000 inches nominal

  • Operating Voltage Rating And Type Per Function

    115.0 volts ac 1st radio interference 1st function

  • Body Material

    metal

  • Source Impedance Rating Per Function

    50.0 ohms 5th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Operating Temp Range

    -54.0/+85.0 deg celsius

  • Operating Current Rating Per Function In Amps

    1.3 2nd radio interference

  • Special Features

    12 functions

  • Operating Voltage Rating And Type Per Function

    24.0 volts dc 5th radio interference 5th function

  • Operating Current Rating Per Function In Amps

    1.3 3rd radio interference

  • Operating Current Rating Per Function In Amps

    1.3 4th radio interference

  • Operating Voltage Rating And Type Per Function

    24.0 volts dc 6th radio interference 6th function

  • Maximum Voltage Drop Per Function

    1.2 volts ac 5th radio interference

  • Load Impedance Per Function

    50.0 ohms 6th radio interference

  • Operating Current Rating Per Function In Amps

    1.3 5th radio interference

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Operating Current Rating Per Function In Amps

    1.3 6th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 5th radio interference

  • Maximum Voltage Drop Per Function

    1.2 volts ac 2nd radio interference

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    6.375 inches nominal

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference

  • Body Width

    5.750 inches nominal

  • Source Impedance Rating Per Function

    50.0 ohms 6th radio interference

  • Overall Length

    7.000 inches nominal

  • Input Terminal Identification

    10-521253-21p

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    5.875 inches nominal

  • Operating Voltage Rating And Type Per Function

    115.0 volts ac 2nd radio interference 2nd function

  • Maximum Voltage Drop Per Function

    1.2 volts ac 3rd radio interference

  • Overall Width

    6.500 inches nominal

  • Body Length

    5.500 inches nominal

  • Load Impedance Per Function

    50.0 ohms 4th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd radio interference

  • Mounting Slot Width

    0.125 inches nominal

  • Operating Voltage Rating And Type Per Function

    115.0 volts ac 3rd radio interference 3rd function

  • Maximum Voltage Drop Per Function

    1.2 volts ac 4th radio interference

  • Input Terminal Manufacturer Code

    77820

  • Operating Current Rating Per Function In Amps

    1.3 1st radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Load Impedance Per Function

    50.0 ohms 5th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th radio interference

  • Operating Voltage Rating And Type Per Function

    24.0 volts dc 4th radio interference 4th function

  • Maximum Voltage Drop Per Function

    1.2 volts ac 6th radio interference

  • Maximum Temp Rise

    25.0 deg celsius

  • Maximum Voltage Drop Per Function

    1.2 volts ac 1st radio interference

  • Inclosure Type

    encased

  • Mounting Facility Type And Quantity

    4 slot

  • Power Line Frequency Rating Per Function In Hertz

    400.0 2nd radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 6th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 3rd radio interference

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...