NSN: 5915-01-096-5517
Filters and Networks
FILTER,BAND PASS
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Source Impedance Rating Per Function
50.0 ohms 1st band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
1.3 1st band pass
-
Voltage Standing Wave Ratio Per Function
1.5 1st band pass
-
Specified Frequencies Of Discrimination Per Function
3.115 megahertz 2nd band pass and 3.115 megahertz 1st band pass and 2.895 megahertz 2nd band pass and 2.80 megahertz 2nd band pass and 2.80 megahertz 1st band pass and 2.895 megahertz 1st band pass and 3.228 megahertz 2nd band pass
-
Body Length
5.748 inches nominal
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd band pass
-
Voltage Standing Wave Ratio Frequency Limits Per Function
3.115 hercules no.5599.1 two phase to two phase
-
Frequency Band Width Per Function
3.115 megahertz 1st band pass
-
Body Width
1.620 inches nominal
-
Load Impedance Per Function
50.0 ohms 2nd band pass
-
Operating Temp Range
+0.0/+50.0 deg celsius
-
Reference Frequency Per Function
3.005 hercules no.5599.1 two phase to two phase
-
Functional Terminal Type And Quantity
1 connector, receptacle output 2nd function
-
Average Power Rating Per Function
20.0 watts 2nd band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 minimum 1st band pass and 3.0 minimum 2nd band pass and 60.0 maximum 2nd band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
60.0 maximum 1st band pass
-
Inclosure Type
hermetically sealed
-
Mounting Facility Type And Quantity
2 slot
-
Average Power Rating Per Function
20.0 watts 1st band pass
-
Mounting Slot Width
0.085 inches nominal
-
Reference Frequency Per Function
3.005 hercules no.5599.1 pulses per second
-
Principal Circuitry Type Per Function
inductance-capacitance 1st band pass
-
Frequency Band Width Per Function
2.895 megahertz 2nd band pass and 2.895 megahertz 1st band pass and 3.115 megahertz 2nd band pass
-
Load Impedance Per Function
50.0 ohms 1st band pass
-
Source Impedance Rating Per Function
50.0 ohms 2nd band pass
-
Overall Height
0.620 inches nominal
-
Style Designator
rectangular terminal/terminals on opposite surfaces
-
Overall Width
2.372 inches nominal
-
Unpackaged Unit Weight
1.000 pounds
-
Voltage Standing Wave Ratio Frequency Limits Per Function
2.895 hercules no.5599.1 pulses per second and 2.895 hercules no.5599.1 two phase to two phase and 3.115 hercules no.5599.1 pulses per second
-
Voltage Standing Wave Ratio Per Function
1.5 2nd band pass
-
Functional Terminal Type And Quantity
1 connector, receptacle input 1st function
-
Body Material
metal
-
Insertion Loss At Reference Frequency Per Function In Decibels
1.3 2nd band pass
-
Overall Length
6.500 inches nominal
-
Specified Frequencies Of Discrimination Per Function
3.228 megahertz 1st band pass