NSN: 5915-01-097-6662
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Overall Length
15.000 inches nominal
-
Inclosure Type
hermetically sealed
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
8.000 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
3.500 inches nominal
-
Nominal Thread Size
0.250 inches
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 1st radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 3rd radio interference
-
Body Height
11.900 inches nominal
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Body Width
4.500 inches nominal
-
Body Length
10.000 inches nominal
-
Body Material
metal
-
Functional Terminal Type And Quantity
1 connector, receptacle input 1st function
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Style Designator
rectangular terminal/terminals on opposite surfaces
-
Mounting Facility Type And Quantity
6 threaded hole
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Operating Voltage Rating And Type Per Function
208.0 volts ac 1st radio interference 1st function
-
Functional Terminal Type And Quantity
3 threaded stud output 2nd function
-
Operating Temp Range
-45.6/+71.0 deg celsius
-
Operating Current Rating Per Function In Amps
110.0 1st radio interference
-
Operating Voltage Rating And Type Per Function
208.0 volts ac 2nd radio interference 2nd function
-
Operating Voltage Rating And Type Per Function
208.0 volts ac 3rd radio interference 3rd function
-
Operating Current Rating Per Function In Amps
110.0 2nd radio interference
-
Operating Current Rating Per Function In Amps
110.0 3rd radio interference
-
Mounting Facility Screw Thread Series Designator
unf
-
Power Line Frequency Rating Per Function In Hertz
400.0 2nd radio interference