NSN: 5915-01-157-9579
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Operating Voltage Rating And Type Per Function
250.0 volts ac 2nd radio interference 2nd function and 400.0 volts dc 2nd radio interference 2nd function
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Power Line Frequency Rating Per Function In Hertz
420.0 2nd radio interference
-
Style Designator
rectangular terminal/terminals on opposite surfaces
-
Unpackaged Unit Weight
4.500 pounds
-
Power Line Frequency Rating Per Function In Hertz
420.0 3rd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Functional Terminal Type And Quantity
3 threaded stud output 2nd function
-
Operating Voltage Rating And Type Per Function
250.0 volts ac 1st radio interference 1st function and 400.0 volts dc 1st radio interference 1st function
-
Principal Circuitry Type Per Function
inductance-capacitance-resistance 1st radio interference
-
Body Length
6.000 inches nominal
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Functional Terminal Type And Quantity
3 threaded stud input 1st function
-
Principal Circuitry Type Per Function
inductance-capacitance-resistance 2nd radio interference
-
Operating Current Rating Per Function In Amps
12.0 1st radio interference
-
Body Height
2.250 inches nominal
-
Principal Circuitry Type Per Function
inductance-capacitance-resistance 3rd radio interference
-
Operating Current Rating Per Function In Amps
12.0 2nd radio interference
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
5.400 inches nominal
-
Operating Current Rating Per Function In Amps
12.0 3rd radio interference
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Operating Temp Range
-55.0/+85.0 deg celsius
-
Overall Length
7.300 inches nominal
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Average Power Rating Per Function
2.0 watts 1st radio interference
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
6.700 inches nominal
-
Inclosure Type
encased
-
Unthreaded Mounting Hole Diameter
0.147 inches nominal
-
Maximum Dielectric Withstanding Dc Voltage
800.0 volts at sea level
-
Average Power Rating Per Function
2.0 watts 2nd radio interference
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Average Power Rating Per Function
2.0 watts 3rd radio interference
-
Vibration Resistance Range In Hertz
+10.0/+2000.0
-
Operating Voltage Rating And Type Per Function
250.0 volts ac 3rd radio interference 3rd function and 400.0 volts dc 3rd radio interference 3rd function
-
Body Width
6.000 inches nominal
-
Body Material
metal
-
Maximum Temp Rise
30.0 deg celsius
-
Mounting Facility Type And Quantity
8 unthreaded hole
-
Power Line Frequency Rating Per Function In Hertz
420.0 1st radio interference