NSN: 5915-01-158-1090

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

5915 - Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Principal Circuitry Type Per Function

    inductance-capacitance 6th radio interference

  • Operating Current Rating Per Function In Amps

    5.0 5th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 3rd radio interference

  • Operating Current Rating Per Function In Amps

    5.0 6th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 4th radio interference

  • Operating Temp Range

    -55.0/+125.0 deg celsius

  • Overall Length

    2.264 inches nominal

  • Power Line Frequency Rating Per Function In Hertz

    400.0 5th radio interference

  • Maximum Dielectric Withstanding Dc Voltage

    1.5 kilovolts at sea level

  • Precious Material

    silver

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • Output Terminal Manufacturer Code

    11139

  • Power Line Frequency Rating Per Function In Hertz

    400.0 6th radio interference

  • Maximum Voltage Drop Per Function

    2.5 volts ac 1st radio interference and 8.0 volts dc 1st radio interference

  • Operating Voltage Rating And Type Per Function

    250.0 volts ac 6th radio interference 6th function and 800.0 volts dc 6th radio interference 6th function

  • Overall Height

    1.796 inches minimum and 1.828 inches maximum

  • Functional Terminal Type And Quantity

    61 friction w/grounding strap and pin input-output

  • Source Impedance Rating Per Function

    50.0 ohms 5th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Operating Voltage Rating And Type Per Function

    250.0 volts ac 3rd radio interference 3rd function and 800.0 volts dc 3rd radio interference 3rd function

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference

  • Vibration Resistance Range In Hertz

    +10.0/+500.0

  • Source Impedance Rating Per Function

    50.0 ohms 6th radio interference

  • Style Designator

    filter connector

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Operating Voltage Rating And Type Per Function

    250.0 volts ac 2nd radio interference 2nd function and 800.0 volts dc 2nd radio interference 2nd function

  • Load Impedance Per Function

    50.0 ohms 4th radio interference

  • Body Material

    aluminum

  • Operating Voltage Rating And Type Per Function

    250.0 volts ac 1st radio interference 1st function and 800.0 volts dc 1st radio interference 1st function

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd radio interference

  • Precious Material And Location

    contact surfaces silver

  • Maximum Voltage Drop Per Function

    2.5 volts ac 3rd radio interference and 8.0 volts dc 3rd radio interference

  • Maximum Voltage Drop Per Function

    2.5 volts ac 4th radio interference and 8.0 volts dc 4th radio interference

  • Operating Current Rating Per Function In Amps

    5.0 1st radio interference

  • Mounting Facility Screw Thread Series Designator

    unef

  • Maximum Temp Rise

    25.0 deg celsius

  • Operating Current Rating Per Function In Amps

    5.0 3rd radio interference

  • Operating Current Rating Per Function In Amps

    5.0 4th radio interference

  • Operating Voltage Rating And Type Per Function

    250.0 volts ac 5th radio interference 5th function and 800.0 volts dc 5th radio interference 5th function

  • Power Line Frequency Rating Per Function In Hertz

    400.0 2nd radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 5th radio interference

  • Operating Current Rating Per Function In Amps

    5.0 2nd radio interference

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Input Terminal Manufacturer Code

    11139

  • Body Surface Treatment

    cadmium

  • Overall Width

    1.796 inches minimum and 1.828 inches maximum

  • Input Terminal Identification

    mil-c-26482

  • Load Impedance Per Function

    50.0 ohms 6th radio interference

  • Maximum Voltage Drop Per Function

    2.5 volts ac 6th radio interference and 8.0 volts dc 6th radio interference

  • Operating Voltage Rating And Type Per Function

    250.0 volts ac 4th radio interference 4th function and 800.0 volts dc 4th radio interference 4th function

  • Output Terminal Identification

    mil-c-26482

  • Maximum Voltage Drop Per Function

    2.5 volts ac 2nd radio interference and 8.0 volts dc 2nd radio interference

  • Inclosure Type

    hermetically sealed

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th radio interference

  • Special Features

    sixty-one filtered functions

  • Load Impedance Per Function

    50.0 ohms 5th radio interference

  • Nominal Thread Size

    1.625 inches

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Features Provided

    moisture resistant and shock resistant

  • Maximum Voltage Drop Per Function

    2.5 volts ac 5th radio interference and 8.0 volts dc 5th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 1st radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...